Error-Disable Recovery Configuration - ZyXEL Communications GS1350 Series User Manual

Gbe layer 2 poe switch
Hide thumbs Also See for GS1350 Series:
Table of Contents

Advertisement

Table 91 Advanced Application > Errdisable > Errdisable Detect (continued)
L ABEL
Mode
Apply
Cancel
25.6 Erro r- Disa b le Re c o ve ry C o nfig ura tio n
Use this screen to configure the Switch to automatically undo an action after the error is gone. Click the
link next to
C lic k He re
the screen as shown.
Fig ure 150
The following table describes the labels in this screen.
Table 92 Advanced Application > Errdisable > Errdisable Recovery
L ABEL
Active
Reason
*
Timer Status
Interval
DESC RIPT IO N
Select the action that the Switch takes when the number of control packets exceed the rate
limit on a port, set in the
– The Switch disables the port on which the control packets are received.
ina c tive - po rt
– The Switch drops all the specified control packets (such as BPDU) on the
ina c tive - re a so n
port.
– The Switch drops the additional control packets the ports has to handle in
ra te - lim ita tio n
every one second.
Click
to save your changes to the Switch's run-time memory. The Switch loses these
Apply
changes if it is turned off or loses power, so use the
your changes to the non-volatile memory when you are done configuring.
Click
to begin configuring this screen afresh.
C a nc e l
Errdisa b le Re c o ve ry
Advanced Application > Errdisable > Errdisable Recovery
DESC RIPT IO N
Select this option to turn on the error-disable recovery function on the Switch.
This field displays the supported features that allow the Switch to shut down a port or discard
packets on a port according to the feature requirements and what action you configure.
Use this row to make the setting the same for all entries. Use this row first and then make
adjustments to each entry if necessary.
Changes in this row are copied to all the entries as soon as you make them.
Select this check box to allow the Switch to wait for the specified time interval to activate a port
or allow specific packets on a port, after the error was gone. Clear the check box to turn off this
rule.
Enter the number of seconds (from 30 to 2592000) for the time interval.
GS1350 Series User's Guide
>
Adva nc e d Applic a tio n
Errdisa b le
Sa ve
in the
Adva nc e d Applic a tio n
204
>
screen.
C PU pro te c tio n
link on the top navigation panel to save
>
screen to display
Errdisa b le

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs1350-6hpGs1350-12hpGs1350-18hpGs1350-26hp

Table of Contents