5. ELECTRONIC INSTALLATION

F
ALWAYS DISCONNECT THE POWER SUPPLY before
working on the board. Turn power on only after
having made all the electrical connections and carried
out the preliminary start-up checks.
The board cover must never be removed unless the
board is to be replaced. No installation operation
requires the removal of the cover.

5.1 BOARD E614

 4 E614 board technical data
Power supply voltage
Max power
Accessories output voltage
Max. accessories load
Max. BUS 2easy accessories load
Max. flashing light load
Ambient operating temperature

COMPONENTS

See figure  3 0
BOARD:
J1
Mains power supply terminal block
J3
BUS 2easy terminal block
J6
Inputs terminal block
J7
Connector for XF radio module
J8
Connector for battery backup
J10
Terminal block for external detector
J11
Connector for encoder
J13
Terminal block for external detector
J16
Terminal block for external flashing light
J18
Terminal block for the arm lights
J20
Terminal block for outputs
J21
Connector for integrated flashing light
J23
Connector for motor
F1
Board protection fuse (F1 = T5A UL approved)
DISPLAY
Programming display
DL1
BUS 2easy ACTIVE LED
B614
BOARD:
DL2
DL3
DL4
DL5
DL8
LOOP1
DL9
DL10
LOOP2
DL11
DL12
DL13
29
115V~ +/-10% 50/60 Hz
150 W
24 V "
500 mA
500 mA
24 V " 15 W
-4 ° to +131 °F (-20 °C to +55 °C)
BUS 2easy "BUS MON" diagnostic LED
"RADIO1" (OMNIDEC) LED
"RADIO2" (OMNIDEC) LED
Error / alarm LED
EMER
status LED
STOP/FSW-CL
status LED
CLOSE
status LED
OPEN
status LED
LOOP1
status LED
LOOP2
status LED
532297 - Rev.D