11.4 FUSE REPLACEMENT

1. (4 8 ) Remove the fuse F1 cover by gently pry
it off with a screwdriver.
2. Remove the fuse
3. Plug in the new fuse.
4. Replace the fuse cover.
!
Only use a T5A UL approved (delayed) fuse.

11.5 OPERATIONAL PROBLEMS

 10 Troubleshooting
CONDITION
FINDING SOLUTIONS
check the automation is not released
The barrier does not per-
form the SET-UP
check there is power
The barrier does NOT
check the motor and encoder con-
OPEN
nection
The barrier CLOSES rather
invert the phases in the motor connec-
than OPENING and vice
tion and perform a SET-UP
versa.
check the force set
check the balancing of the arm
The barrier makes very
check the parameter
slow movements
accordance with the arm length
if the barrier is being battery operated
make sure the battery is charged.
check the motor connection and make
The barrier moves irre-
sure that the encoder is working cor-
gularly
rectly
check the automation is not released
The barrier does NOT
OPEN
check the motor direction of travel
check the automation is not released
check the motor direction of travel
The barrier does NOT
Check the LED status of the controls,
CLOSE
loops, safety devices and
not active
check the automation is not released
The barrier does NOT
Check the status of the
OPEN and does NOT
not active
CLOSE
check the motor and encoder con-
nection
B614
cF
has been set in
EMER
are
STOP
LED is