Advertisement

Quick Links

E045S

Advertisement

Table of Contents
loading

Summary of Contents for FAAC E045S

  • Page 1 E045S...
  • Page 2 Die Kunden dürfen nur für den Eigengebrauch Kopien anfertigen. Dieses Handbuch wurde 2020 veröffentlicht. © Copyright FAAC S.p.A. del 2020. Todos los derechos están reservados. No puede reproducirse, archivarse, distribuirse a terceros ni copiarse de ningún modo, ninguna parte de este manual, con medios mecánicos o mediante fotocopia, sin el permiso previo por escrito de FAAC S.p.A.
  • Page 3: Table Of Contents

    6.3 Operating logics ........14  1 Technical data E045S....... . . 6 6.4 Setup.
  • Page 4: Eu Declaration Of Conformity

    E045S will be installed, prior to commissioning the machine. These activities include the analysis of all the risks associated with the machine and subsequent implementation of all safety measures intended to fulfil the essential safety requirements.
  • Page 5: Meaning Of The Symbols Used

    Risk of shearing due to moving parts § CHAPTER/SECTION E.g.: §1.1 see section 1.1.  LED off RISK OF IMPACT/CRUSHING/SHEARING Risk of impact, crushing or shearing due to moving parts  LED on   LED flashing  LED flashing quickly E045S 532373 - Rev.A...
  • Page 6: Safety Recommendations

    The required level of workplace lighting must be equal to at least 200 lux. Operate CE marked machinery and equipment in com- pliance with the manufacturer's instructions. Use E045S 532373 - Rev.A...
  • Page 7: E045S

    - It is prohibited to use and/or install accessories which have not been specifically authorised by FAAC S.p.A. - It is prohibited to use the E045S in the presence of faults which could compromise safety. - Do not allow water jets of any type or size to come into direct contact with the E045S.
  • Page 8: Technical Specifications

    3.5 TECHNICAL SPECIFICATIONS Technical data E045S  1 E045S It is an electronic board designed to control one Power supply voltage 207…253 V~ 50/60 Hz or two 230 V~ motors with an overall power of 800 Max power stand-by: 4.3 W W (800 W refers to the sum of the loads connected to Max.
  • Page 9: Installation Requirements

    It is recommended to position the control acces- sories within the field of view of the automation. This is mandatory in the case of hold-to-run controls. E045S 532373 - Rev.A...
  • Page 10: Components

    Led STOP STOP input status Removable terminal board for connecting control devices USB LED USB pen drive present Connector (3 pin) for FAAC XF radio module BUS LED Bus 2easy devices USB-A port BUS MON LED Bus 2easy line Removable terminal board for accessories power supply "...
  • Page 11: Connections

    9 OP-A of pulse generator which, by closing a contact, com- mands the total opening (OPEN) of the gate. The E045S supplies 24 V " and is short-circuit pro- " 24 V tected with a maximum current of 500 mA for con- 3 W max nected accessories.
  • Page 12: Electric Lock

    60 W max 230 V~ Use an FAAC 12 V~/24 V " electric lock or a generic 24 COM Motor COMMON contact V " /0.5 A electric lock with a maximum current of 3 A.
  • Page 13: Mains Power Supply

    , then the FW version (e.g. ), then (SETUP required). If the SETUP has already been carried out , appears on the display and then the automation status (e.g. For LED and display signals see § Diagnostics. E045S 532373 - Rev.A...
  • Page 14: Programming

    (Adjustment step: 10 s) 3. Press button to confirm: the display reverts to Learn BUS 2easy devices the automation status view. See the relative section. MOTOR 2 OPERATION in dead man mode (displayed only if OPEN (displaying CLOSE (displaying E045S 532373 - Rev.A...
  • Page 15: Advanced Programming Menu

    Enables/disables pre-flashing of 3 sec. before each movement. disabled enabled ANTI-CRUSHING SENSITIVITY (displayed only if This function species the speed with which the anti-crushing system triggers after an obstacle has been detected. … (levels, =maximum sensitivity) E045S 532373 - Rev.A...
  • Page 16: Operating Logics

    OPEN during the pause, resets the pause time. OPEN during opening, is ignored. OPEN during closing, causes it to reopen. The triggering of the closing photocells: during pause, reloads the pause time. E045S 532373 - Rev.A...
  • Page 17: Setup

    , see  SETUP phases). If the SETUP procedure doesn’t start or stops before it has been completed, the board exits from program- ming mode and flashes on the display: check the ERRORS that are present (§ Diagnostics). E045S 532373 - Rev.A...
  • Page 18: Configuring Movements And Timing

    When an obstacle is detected, the board also issues a reverse command. Obstacle detection is via the encoder (if present) or via E045S 532373 - Rev.A...
  • Page 19: Putting Into Service

    7. PUTTING INTO SERVICE 8.1 BUS 2EASY DEVICES 7.1 FINAL CHECKS It is possible to connect FAAC BUS 2easy devices (pho- 1. Make sure that the forces generated by the gate tocells, sensitive edges, control devices) to this board. are within the limits permitted by the current regulations.
  • Page 20: Bus 2Easy Sensitive Edges

    1. Assign an address to the device electronics by setting the four DIP switches. No two devices should have the same DIP switch set- tings. If there is more than one device with the same address, a conflict error is generated. E045S 532373 - Rev.A...
  • Page 21: Bus 2Easy Control Devices

    1 1 1 0 1 Open A_4 StopNC_2* 1 1 1 1 0 / 1 1 1 1 1 Open A_4 Close MOT2 MOT1 MOT1 MOT2 DL2 on = encoder connected to MOT1 DL2 off = encoder connected to MOT2  5 E045S 532373 - Rev.A...
  • Page 22: Bus 2Easy Status

    Closing photocells Photocells for Open impulse Opening/closing photocells Close control device Opening photocells Stop control device Closing sensitive edge Encoder - leaf 2 Not used Opening sensitive edge BUS 2easy status Encoder - leaf 1 6 E045S 532373 - Rev.A...
  • Page 23: Xf Radio Module

    8.2 XF RADIO MODULE RADIO CONTROLS SLH/SLH LR Memorise the first radio control, MASTER, on the E045S is fitted with an OMNIDEC integrated two board. Then add other radio controls that are re- channel decoding system that can memorise, via the quired following the learning procedure that doesn’t...
  • Page 24: Radio Controls - Rc/Lc

    20 s). The procedure ends after 20 s if no further radio con- trols are memorised (the corresponding RADIO LED switches off). To add additional radio controls, repeat the procedure from step 1. E045S 532373 - Rev.A...
  • Page 25: Upload/Download

    9. UPLOAD/DOWNLOAD DOWNLOAD OPERATIONS There is a USB port on the E045S board that can be used for the following: Display Function File name - Load data from a USB pen drive (UPLOAD) Download board configuration E045.prg - saving data to a USB pen drive (DOWNLOAD).
  • Page 26: Diagnostics

    (*) Additional LED status or meanings are shown in the section on the accessory to which it refers. colour meaning    ERROR Error/alarm signalling alarm in progress error in progress not active E045S 532373 - Rev.A...
  • Page 27: Errors

     10 Errors  11 Alarms Board failure Perform RESET. If the problem Obstacle de - An obstacle that prevents the leaf persists, replace the E045S. tected Leaf1 from moving has been detect- ed. Remove the obstacle. SETUP incorrect/ Perform SETUP.
  • Page 28: Maintenance

     12 lists the operations that should be performed N in industrial or commercial settings. on a regular basis on the E045S board in order to Check that the sensitive edges operate correctly when an keep the automation working reliably and safely;...
  • Page 32 FAAC S.p.A. Soc. Unipersonale Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY Tel. +39 051 61724 - Fax +39 051 09 57 820 www.faac.it - www.faacgroup.com E045S 532373 - Rev.A...

Table of Contents