Determine The Orientation Of The Installation - FAAC 620 Installation Manual

Barrier gate operator/control panel
Hide thumbs Also See for 620:
Table of Contents

Advertisement

P a g e 8
WARNING! Do not install the barrier in such a
way that the beam moves within 2 feet (610
mm) of a rigid object.
Installing the 620 or 640 Barrier System consists of the
following general steps:
Determining the orientation of the installation
Preparing the forms for the concrete mounting
slab and conduit
Mounting the cabinet on the concrete slab
Connecting the main power source to the
operator
Wiring the control panel for operational logic
Wiring additional accessories into the control
panel
Decreasing the hydraulic pressures
Programming the control panel
Attaching the barrier beam
Testing the operation of the beam
Note:
The
following
assume you are fully capable of installing an
electronic barrier gate. This manual does not
instruct you in designing a gate, pouring the
cement foundation, or basic electrical wiring. The
installation tasks discussed in this manual are
tasks peculiar to the 620 and 640 Barriers.
Figure 3. Right Hand vs. Left Hand Installation of the 620/640 Barrier
I
NSTALLING THE
installation
instructions
(a) Right-hand orientation: top view and hose connections
Beam side
Compression
Panel
spring
Cabinet
side
(b) Left-hand orientation: top view and hose connections
Beam
Cabinet
Compression
spring
6 2 4B LD C ontr ol Pa ne l Ins tal la tion M a nual
B
ARRIER
D
O
ETERMINE THE
RIENTATION OF THE
You first need to determine whether your operator is set
up for a right-hand or left-hand installation (see Figure 3).
Open the panel door of the operator cabinet with the key
provided and lift the door up and away from the cabinet,
taking care not to disconnect the cabling to the fan. Look
at the two pistons to see which has the compression
spring surrounding it. Compare your operator with Figure
3 and use the figure to help you determine the orientation
of your installation.
If your operator is not in the correct orientation, turning
the cabinet around 180 deg is the easiest way to solve the
problem. We suggest you call us if your installation site
cannot accommodate this solution since the orientation of
the barrier can be changed with about an hour's worth of
work.
NOTE: It make no difference if the
hoses are crossed or not.
Beam
Beam side
Panel
side
Ja nua ry , 2 00 7
6 2 0 /6 40 O pera tor An d
I
NSTALLATION

Advertisement

Table of Contents
loading

This manual is also suitable for:

624bld640