momentarily and checking the change of status of the
input. If the test fails the electronic board does not
command the movement.

EXTERNAL LOOPS

!
The magnetic loop detectors must not be used to
detect pedestrians, cycles and motorbikes. If it
necessary to detect them, other devices such as
photocells are needed.
( 3 2) Connect the magnetic detectors to terminal
boards J10
(LOOP
1) or J13
Opening coil NO contact
LOOP 1
Connect a detector that, when the contact is closed (loop
engaged), commands the opening
Transit coil NO contact
Connect a detector that, when the contact is closed (loop
engaged), works according to the set functioning logic:
all logics, except P As long as the loop is engaged,
it prevents closing. If the loop is engaged during the
LOOP 2
closing, it commands the inversion on opening.
only in logic P The loop commands the closing at the
disengagement. If the loop is engaged during the
closing, it commands the stop (disengage the loop to
complete the closing)

BUS DEVICES

If no BUS 2easy devices are used, leave the BUS 2easy
terminal board free.
See the chapter § 8.4 for the connection and
orientation.
OUT
OUTPUTS
Do not exceed 100mA max load for each output.
Open Collector Outputs: the activation of the output
and its polarity can be configured by Advanced pro-
gramming.
OUT
active
0 V "
NO polarity
NC polarity
open circuit
( 3 3 ) Connect the devices required to terminal
block J20.
"
24 V

FLASHING LIGHT

See the chapter § 8.1 for the connection.

MOTOR

(34) The motor wire is connected from the factory
for a RH barrier.
Invert the wires if a LH barrier is being installed.
B614
(LOOP
2).
OUT
not active
open circuit
0 V "
J10
J20
red
M
blue
32
J13
32
J3
33
AC MAI
MOT
J23
MOT
J11
ENC
34
532297 - Rev.D