3. ELECTRONIC EQUIPMENT JE275
!
Before performing any work on the electronic equipment (connections, maintenance), always turn the power off.
Install a differential thermal breaker upstream with adequate tripping threshold (0.03A).
Connect the ground cable to the terminal on the J9 connector on the equipment (14).
Check that the mains switch is equipped with a locking key, unless this is fitted under the supervision of the operator/maintainer
The equipment must be installed at a height between 0.4 m and 2.0 m.

3.1 ELECTRICAL CONNECTIONS

JE275 BOARD SIDE
J9
MOT2
COM
MOT1
FAN
COM
COM
LAMP
J2
GND
OUT 4
OUT 3
OUT 3
OUT 2
OUT 1
+24 V
+24 V
GND
GND
EMERGENCY
STOP
FSW
CLOSE
OPEN A
LOOP 2
LOOP 2
LOOP 1
LOOP 1
J1
EFO N.O. connection (activtes also in case of black out)
GND
EMERGENCY
4
5
Bollard side
www.FastGateOpeners.com | (800) 878-7829 | Sales@FastGateOpeners.com
L N
A1
1
3
2
4
J3
J5
Limit switch
UP
Limit switch
DOWN
R1
R1
230 V~
Board side
BOLLARD SIDE
A1
5
13
A1
Contactor
6
14
A2
CL
Solenoid valve
EFO
solenoid valve
Heater
(optional)
EFO pressure
switch
EFO N.C. connection (voluntary activation only)
GND
EMERGENCY
4
5
Bollard side
FG7OR - 3G4
FG7OR - 16G1,5
Motor
COM
AP
PE
1
2
3
4
Refer to the
diagram below
5
6
230 V ~
7
230 V ~
8
+24V
+24V
9
Lights
10
Limit switch UP
11
Limit switch DOWN
Limit switch common
12
R1
R1
230 V~
Board side
14