Summary of Contents for FAAC J275 2K HA

  • Page 1 J275 2K HA...
  • Page 2 Nessuna parte di questo manuale può essere riprodotta, archiviata, distribuita a terzi né altrimenti copiata, in qualsiasi formato e con qualsiasi mezzo, sia esso elettronico, meccanico o tramite fotocopia, senza il preventivo consenso scritto di FAAC S.p.A. Tutti i nomi e i marchi citati sono di proprietà dei rispettivi fabbricanti.
  • Page 3: Table Of Contents

    3. J275 2K HA ........
  • Page 4: Introduction To The Instruction Manual

    When drafting the manual, the results of the risk assessment con- WARNING ELECTRIC SHOCK HAZARD - The operation or stage described ducted by FAAC S.p.A. on the entire product life cycle have been taken must be performed following the supplied instructions and applicable into account in order to implement effective risk reduction measures.
  • Page 5: Safety Recommendations

    Use work instruments in good conditions. Use the transport and lifting equipment recommended in the instruc- tions manual. Use safety-compliant portable ladders of adequate size, fitted with anti-slip devices at the top and bottom, equipped with retainer hooks. J275 2K HA 532208 - Rev.A...
  • Page 6: J275 2K Ha

    - It is prohibited to install the automation outside of the limits J275 2K HA •••••• Sale code specified in the Technical Data and Installation Requirements Product name sections. - It is prohibited to use the J275 2K HA in a configuration other MM/YY PROG IDENTIFICATION NUMBER •••••• •••• ••••...
  • Page 7: Technical Characteristics

    15 Internal junction box 16 Release key 17 Head removal key INSTALLATION ACCESSORIES (SUPPLIED SEPARATELY) Subframe Side module with cable routing hole (x1) Cable gland Side module (x7) Base with water drainage holes  2 J275 2K HA 532208 - Rev.A...
  • Page 8: Optional Accessories

    Break-in resistance (STAINLESS STEEL) 414 kJ Break-in resistance (double configuration) 656kJ (M30) Continuous use time (ROT) 110 min at 23°C Load class (EN124) C250 (25 t) 3.8 DIMENSIONAL DRAWING Cover  3  4 J275 2K HA 532208 - Rev.A...
  • Page 9: Installation

    (e.g. an electric pump) that is deeper than the catch basin that collects and discharges the rainwater. 1000 1000   Ground Excavation  5  6 J275 2K HA 532208 - Rev.A...
  • Page 10: Making The Cage

    4.3 MAKING THE CAGE The foundation cage is not supplied by FAAC and has to be made on site. 1.  7 Make and assemble the cage according to the measurements and the number of pieces indicated in the figure.
  • Page 11: Cementing

    The upper surface of the subframe must protrude by approximately 10 mm with respect to the final road surface. Ground Excavation Gravel Concrete  1 0 7. Lay the road surface so that it seals the subframe.  1 1 9 J275 2K HA 532208 - Rev.A...
  • Page 12: Installing The Bollard

    Use belts or chains and a lifting device that are suitable for the weight of the bollard. Take care not to damage the electrical cable by pinching it between the frame and the pit.  1 5 J275 2K HA 532208 - Rev.A...
  • Page 13: Manual Operation

    To reposition or lift the cover, prise one of the two slots upwards using a screwdriver.  1 8 3.  1 9 Insert the key 1 and turn it anticlockwise until it stops 2. 17  1 9 J275 2K HA 532208 - Rev.A...
  • Page 14: Restoring Automatic Operation

    5. Turn the release device anticlockwise using the key provided.    2 3 5.  2 4 Put back the screws 2 and the plug 3. 6. Replace the plugs 1. 21  2 4 J275 2K HA 532208 - Rev.A...
  • Page 15: Electrical System

    With a master-slave configuration it is necessary to position a disconnect switch is not in view, apply a warning sign stating “WARN- tube for the cables connecting the two J275 2K HA. ING - Maintenance in Progress”. Check buried cable plans to ensure that there are no other electrical...
  • Page 16: Board Programming

    After connecting and switching on the power to the control board as per the previous chapter, select the work pre-setting for the bollard J275 2K HA by performing the following operation: 1. Access level 1 programming by holding down the F button on the board (26).
  • Page 17 LAMP OUT 4 4 5 6 OUT 3 OUT 3 OUT 2 OUT 1 +24 V +24 V EMERGENCY STOP CLOSE OPEN A LOOP 2 LOOP 2 LOOP 1 LOOP 1  2 8 J275 2K HA 532208 - Rev.A...
  • Page 18: Troubleshooting

    5 on the JE275 board (§3.2) The flashing LED light is not working Make sure that the power supply connector located under the head is plugged in correctly. Check the accessories fuse on the JE275 board. J275 2K HA 532208 - Rev.A...
  • Page 19: Maintenance

     30 Do not modify the original components in any way. FAAC S.p.A. disclaims any liability for damage caused by components that are modified or tampered with. 5. Completely remove the hydraulic unit from the bollard. The warranty shall be forfeited in the event of tampering with com- Use the handle provided to lift the hydraulic unit.
  • Page 20: Topping Up The Oil Level

    Check the drainage. Clean the sliding guides Make sure that there are no oil leaks Top up the oil level, if necessary. Only use FAAC oil Check the condition of the actuator cables, the cable glands and junc- tion boxes.
  • Page 21: Installing Optional Equipment

    OUT 4 OUT 3 OUT 3 OUT 2 OUT 1 +24 V +24 V Master JE275 board 35 Nm EMERGENCY STOP Pink Violet CLOSE  37 Blue Blue 3 5 J275 2K HA 532208 - Rev.A...
  • Page 22: Installing The Solenoid Valve

    Follow the connection diagrams below. MOT2 Rapid lowering MOT1 3 9 5. Install the control coil onto the solenoid valve. LAMP Standard lowering Mains voltage (230V)  4 2 4 0 J275 2K HA 532208 - Rev.A...
  • Page 23: Multiple Connections

    MOT2 MOT1 LAMP 4 4  1 Double confi guration installation (M30) Make a hole as in indicated below in order to obtain a class M30 break-in resistance. 3500 ≤1200  4 6 J275 2K HA 532208 - Rev.A...
  • Page 24 FAAC S.p.A. Soc. Unipersonale Via Calari, 10 - 40069 Zola Predosa - BOLOGNA - ITALY Tel. +39 051 61724 - Fax +39 051 758518 www.faac.it - www.faacgroup.com J275 2K HA 532208 - Rev.A...