ADVANCED PROGRAMMING

1. Press and hold down F and then
until the first advanced function appears. (Each
function is displayed as long as F remains
pressed).
2. Release: the value of the function appears
(default or programmed).
+
or - button to modify the value.
3. Use the
4. Press F to confirm the value displayed. Go
to the next function. The modified value
becomes effective immediately.
Proceed in the same way for all the functions. The last function
St
(
) allows you to close the program.
St
Y
no
5. In
select
or
using the
Y
= save the new program
no
= DO NOT save the new program
6. Press F to confirm and close the program. It returns to the
automation status view.
To exit from the programming mode at
any time:
press and hold down F and then - as well to
St
move directly to
.
B614
+
as well,
+
+
F
+
F
+
+
-
F
+ +
/ - buttons:
+
-
F
 5 Basic programming
Basic function
cF
BARRIER CONFIGURATION
Set functional parameters (including opening
and closing speed) dependent on the arm length.
01
arm up to 3m
02
arm from 3m to 4m
03
arm from 4m to 5m
dF
DEFAULT
Displayed if the board is configured with the
factory settings (default).
Y
indicates that all set values correspond to
the defaults
no
indicates that one or more set values are
different from the defaults
Y
Select
if you wish to restore the default
configuration.
Ct
MASTER/SLAVE
configuration.
MA
Configures the board in
SL
Configures the board in
The following parameters are not
displayed on the Slave board:
P A
b u
t L
-
-
relative section.
LO
FUNCTIONING LOGIC
EP
Semi-automatic step by step
A
Automatic
AP
Automatic step by step
b
Semiautomatic B
bC
Semiautomatic B on opening/person
present C on closure
C
Person present
P
Car park
PA
Automatic Parking
See the dedicated section for the
functioning of the logics
PA
PAUSE TIME
00
Adjustable from
a
If 59 is exceeded, the display changes to indicate
minutes and tens of seconds (separated by a dot)
and can be adjusted in steps of 10 seconds, up to
a maximum of 9.5 minutes.
E.g.: if the display indicates
time is 2 min and 50 sec.
So
OPENING SPEED
01
minimum speed
10
maximum speed
Sc
CLOSING SPEED
01
minimum speed
10
maximum speed
35
Default
Master
mode
Slave
mode
LO
-
P F
t
b F
-
-
-
. See the
59
s, to 1 sec steps.
2.5
, the
See table
Default speed
532297 - Rev.D
03
Y
MA
EP
20