6.2 OPERATING LOGICS

In all the logics:
- the
STOP
command has the priority and stops the
automation system from working
- the
EMERGENCY
command has the priority and opens
the automation system.
EP
- SEMI-AUTOMATIC STEP BY STEP
EP
The
logic requires the use of just the
mand:
-
OPEN
when the barrier is closed, it commands the
opening.
-
OPEN
when the barrier is open it commands the

closing.

-
OPEN
during the movement it stops
-
OPEN
after the stop, it reverses in movement.
The
CLOSE
command always commands the closing.
A
- AUTOMATIC
A
Logic
only requires the
-
OPEN
when the barrier is closed, it commands the
opening. After the pause time, the barrier closes
again automatically.
-
OPEN
when the barrier is open in pause mode, it
reloads the pause time. (Even the intervention of
the photocells reloads the pause time)
-
OPEN
during opening is ignored.
-
OPEN
during opening causes it to open again.
The
CLOSE
command always commands the closing.
AP
- AUTOMATIC STEP-BY-STEP
AP
The
logic requires the use of just the
mand:
-
OPEN
when the barrier is closed, it commands the
opening. After the pause time, the barrier closes
again automatically.
-
OPEN
when the barrier is open in pause mode it
locks. (Even the intervention of the photocells
during the pause mode reloads the pause time)
-
OPEN
during the opening locks.
-
OPEN
during opening causes it to open again.
The
CLOSE
command always commands the closing.
b

- SEMI-AUTOMATIC B

b
Logic
requires the use of the
commands:
-
OPEN
when the barrier is closed, it commands the
opening.
-
CLOSE
when the barrier is open it commands the
closing.
-
CLOSE
during opening it causes reclosing.
-
OPEN
during opening causes it to open again.
B614
OPEN
OPEN
command:
OPEN
OPEN
and
CLOSE
bC
- SEMIAUTOMATIC
C
PRESENT
ON CLOSING
bC
logic requires the use of the
opening and
activation of the
intentional and the barrier must be visible.
-
OPEN
when the barrier is closed, it commands the
opening.
- Maintained
com-
C

- DEAD-MAN

C
Logic
requires the use of maintained
CLOSE
commands. The control must be activated
intentionally and the barrier must be visible.
- Maintained
- Maintained
- If the photocells are triggered, movement is
stopped.
P

- PARKING

P
Logic
requires the use of the
commands:
-
OPEN
when the barrier is closed, it commands the
opening.
-
CLOSE
when the barrier is open it commands the
closing.
-
CLOSE
during opening it causes reclosing after
opening.
-
OPEN
during opening causes it to open again.
- The triggering of the photocells during closing
stops the movement, on disengagement the barrier
continues to close.
PA
- PARKING AUTOMATIC
com-
PA
Logic
requires the
to be used.
-
OPEN
when the barrier is closed, it commands the
opening. After the pause time, the barrier closes
again automatically.
-
OPEN
when the barrier is open in pause mode, it
reloads the pause time. (Even the intervention of
the photocells reloads the pause time)
-
CLOSE
when the barrier is open it commands the
closing.
-
CLOSE
during opening it causes reclosing after
opening.
-
OPEN
during opening causes it to open again.
- The triggering of the photocells during closing
stops the movement, on disengagement the barrier
continues to close.
38
b
ON OPENING/ PERSON
OPEN
CLOSE
maintained on closing. The
CLOSE
command on closing must be
CLOSE
commands the closing.
OPEN
commands the opening.
CLOSE
commands the closing.
OPEN
OPEN
and
CLOSE
532297 - Rev.D
command on
OPEN
and
and
CLOSE
commands