Removal Of Electronic Expansion Valve - Gree U-Match 5 Series Manual

Table of Contents

Advertisement

GREE
Note: Before removing the condenser, make sure there is no refrigerant in the pipeline and power is cut off.
Step
7. Secure the electric box and
arrange the wires according
to the requirement.
8. Check and open the upper
and side panels.
Model: GUD100W/NhA-T, GUD125W/NhA-T, GUD140W/NhA-T, GUD100W/NhA-X, GUD125W/NhA-X,
GUD140W/NhA-X
Note: Before removing the electronic expansion valve, make sure there is no refrigerant in the pipeline and power is cut off.
Step
1. Remove the electric box.
Removal of condenser
Picture

Removal of electronic expansion valve

Picture
126
U-Match 5 SERIES UNIT SERVICE MANUAL
Put the electric box in place and
tighten up the screws of electric
box.
Arrange and secure the wires as
original.
Check whether each component
and connection wire is well
connected.
If everything is OK, place back
the upper, left and right side
panels.
Work instruction
Remove the upper, lower and
front panels.
Loosen the wire clamp at the
bottom of the electric box
Unscrew the screws of
electric box.
The connection wires inside
and outside the electric box
should be removed.
When removing the electric
box, be careful to protect the
components.
Work instruction