Refer to the following table for the resistance between any two terminals:
Compressor model
QXF-A102zE170B
QXF-B141zF030F
QXFS-D25zX090H
QXFS-D32zX090D
QXFS-D32zX090C
QXFS-F428zX450E
QXFS-F428zX450I
Measure the earth resistance of each wiring terminal. The resistance should be above 10 megohm. If not, we
can judge that the compressor is faulted inside.
Step 3:
On condition that the unit cannot be started up, we also need to check the solenoid valve assembly of the
system, including the electronic expansion valve. The checking method is the same as instructed above.
Step 4:
Check whether the IPM module is normal. Please refer to the IPM checking method in the section of
troubleshooting.

4.4.2.2 Replacement of compressor

Step 1: Preparation

(1) Prepare the components for replacement

When carrying the old and new compressors, do not place the compressors horizontally or upside down. The
angle of inclination should be within ±30°. Make sure the lubricant inside the compressors will not flow from the oil
balance mouth. The suction and exhaust openings of the compressors must be sealed. If a rubber seal is missing,
user adhesive tape to seal the opening. This is to prevent the compressor oil from contacting the air.
UV Winding resistance
1.73±7%Ω
1.01±7%Ω
1.11±7%Ω
0.85±7%Ω
1.33±7%Ω
0.63±7%Ω
0.79±7%Ω
99
U-Match 5 SERIES UNIT SERVICE MANUAL
VW Winding resistance
1.73±7%Ω
1.01±7%Ω
1.11±7%Ω
0.85±7%Ω
1.33±7%Ω
0.63±7%Ω
0.79±7%Ω
WU Winding resistance
1.73±7%Ω
1.01±7%Ω
1.11±7%Ω
0.85±7%Ω
1.33±7%Ω
0.63±7%Ω
0.79±7%Ω