Step
8. Install the water tray.
Step
1. After removing the front
panel as instructed above,
loosen the screws of the
water tray.
2. Remove the cover of
electric box and the clamp
of power cord.
3. Remove the motor wire and
water pump wire.
4. Remove the water tray.
Removal of fan and motor
Note: Before removing the motor, power must be cut off.
Picture
Removal and installation of drain pump
Picture
U-Match 5 SERIES UNIT SERVICE MANUAL
142
Work instruction
Direct the 4 corners of water
tray to the 4 corners of the unit
and then press them. Use a
screwdriver to tighten the
screws in the 4 corners.
Connect the power cord and
water pump wire.
Place back the cover of electric
box and the clamp of power
cord. Then tighten the screws
with a screwdriver.
Work instruction
Use a screwdriver to loosen the
screws of water tray.
Twist off the screws and open
the cover of electric box and the
clamp of power cord.
Remove the motor wire and
water pump wire in the electric
box.
Loosen the screws in the 4
corners and then remove the
water tray.