GREE
Note: Before removing the compressor, make sure there is no refrigerant in the pipeline and power is cut off.
Step
2. Loosen the securing screws
at the foot of compressor.
3. Break off the pipes that
connecting to the compressor.
4. Remove the compressor from
the chassis.
5. Fix the new compressor back
onto the chassis.
U-Match 5 SERIES UNIT SERVICE MANUAL
Removal of compressor
Picture
109
Work instruction
Use a wrench to twist off the
screws at the foot of
compressor.
Weld the pipes that are
connected to the
compressor.
Then remove the pipes.
Note: When welding the
pipes, do not let the flame
burn the other components.
Take out the compressor and
replace it.
Note: When replacing the
compressor, avoid touching
the nearby pipeline and
components.
After replacing the
compressor, tighten up the
screws at the foot of
compressor.