Gree U-Match 5 Series Manual page 136

Table of Contents

Advertisement

GREE
Note: Before removing the compressor, make sure there is no refrigerant in the pipeline and power is cut off.
Step
7. Connect the compressor
wires.
Model: GUD160W/NhA-X
Note: Before removing the 4-way valve, make sure refrigerant is fully discharged from the unit and power is cut off.
Step
1. Take off the coil of the 4-way
valve.
2. Break off the connection
pipes from the 4-way valve.
Disassembly of compressor
Picture
Removal of 4-way valve
Picture
133
U-Match 5 SERIES UNIT SERVICE MANUAL
Connect the compressor
wires to the wire terminals
on the top of compressor.
Note: When connecting the
wires, be sure to match the
colors with the
corresponding wire
terminals.
Work instruction
Carefully unscrew the
screws of electromagnetic
coil with a screwdriver.
Use a soldering gun to
loosen the 4 joints on the
4-way valve and then
remove the connection
pipes.
Note: When welding the
pipes, the 4-way valve
should be wrapped with wet
cloth for cooling. Do not let
the flame burn the other
components.
Work instruction

Hide quick links:

Advertisement

Table of Contents
loading