Removal Procedure; Removal Procedure Of Indoor Unit - Gree GWC12ATCXB-K6DNA1B Service Manual

Table of Contents

Advertisement

11. Removal Procedure

11.1 Removal Procedure of Indoor Unit

Step
Before disassemble
Turn off the air conditioner and disconnect the power
before disassemble the air conditioner.
1. Remove filter
Hold the handle on the filter, pull it upwards to let the
clasp at the top part of the filter loose, pull it forwards
and then the filter can be pulled out.
2. Remove guide louver
Push out the plug pin on guide louver, bend the guide
louver with hand and then separate the guide louver
from the crank shaft of step motor to remove it.
74
Caution: discharge the refrigerant
completely before removal.
Procedure
Filter
Handle
Service Manual
Guide Louver
Installation and Maintenance

Advertisement

Table of Contents
loading

Table of Contents