Machine Components; Display; Selection Keyboard; Door Lock - LAVAZZA Magystra LB 2600 INT Installation And Maintenance Manual

Table of Contents

Advertisement

EN

DISPLAY

The display messages inform users and operators about
the operation state of the vending machine.

SELECTION KEYBOARD

In programming mode, the keys assume different func-
tions and enable the operator to modify the machine
parameters. Keys are progressively numbered from the
left to the right.

DOOR LOCK

The door is closed by means of a lock. The key is
mapped and numbered for identification.

DOOR SWITCH

To open the door unlock the side lock with the key.
Whenever you open the door, a special switch will
power off the electric installation of the equipment.
To power the system with the door open, simply use
the special service key. The key is located in a prop-
er housing of the top cover.
When the door is open, you are not allowed to
access any live part .
Only the parts protected by covers and signalled
by the label "power off before removing the cov-
er" remain live inside the machine .
Before removing these covers, detach the power
supply cable from the mains .
Before closing the doors be sure to have removed
the service key, if any.
12

MACHINE COMPONENTS

FLAP FOR CAPSULES

Arranged on the front panel of the vending machine; it
opens as a swing door to the right and houses the coffee
capsule that must be inserted in the correct direction.
While entering the capsule unit, the new capsule pushes
the capsule that has been inserted into the exhausted
capsule canister before.

DISPENSER

The LB 2600 vending machine has a fixed drink dis-
penser on the cup support surface and a flap support for
small cups. The dispensing compartment, in stand-by,
is lit up by a led turning off during the dispensing cycle
and turning on again as soon as the drink can be taken.

WATER FLAP

A lid, positioned on the top cover of the dispenser, gives
access to the internal water tank to allow filling. A lock is
available that prevents filling to unauthorized persons.

WATER TANK

The internal water tank is intended to supply the vend-
ing machine and it can be filled through a flap in the
cover of the vending machine, locked so as to prevent
unauthorised people from filling or by opening the cov-
er of the vending machine and extracting it upwards by
means of the handle. A capacitive sensor checking the
water level in the tank is arranged in the vending ma-
chine. When the water level is not enough, a warning
message appears on the display and any dispensing
cycle is inhibited until the water level is restored. A red
floater indicates the maximum filling level of the tank.

CAPSULE GROUP

In the capsule unit, after having inserted the capsule in
the correct position, having closed the lid and having se-
lected the required beverage, infusion takes place with
the water coming from the heating element. The spent
capsule is conveyed to the spent capsule drawer when a
new capsule is inserted for next supply.
Never insert your fingers or any object into the
capsule compartment .
Only capsules compatible ones must be inserted
into the capsule compartment .
Insert one capsule at a time .

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magystra lb 2600 menaMagystra lb 2600 aus

Table of Contents