Frequent Inspections; Periodical Inspections - RaycoWylie i3500 Instruction Manual

Rated capacity indicator system for telescopic cranes pressure sensing, multi-point version
Hide thumbs Also See for i3500:
Table of Contents

Advertisement

6.1 Frequent Inspections (At the beginning of each shift
during which a crane is used)
At system power up, check if all alarm lights are on, buzzer sounds and
lockout are activated.
Verify that the system has been properly configured.
Verify the accuracy of the clock.
Verify that no error has been detected by the system.
Verify the weight of the hook block (must be consistent with last check).
Verify the radius according to the boom selection. The displayed radius
must be between 0 and 10% greater than the actual radius or in
accordance with current regulations.
Verify that the capacity displayed conforms to the capacity chart of the
crane manufacturer.
Verify the functionality of the ATB if fitted.
Warning! Any deficiencies shall be examined and a decision
must be made as to whether they constitute a hazard before
using the machine.
6.2 Periodical inspections (every 6 months)
Inspect at regular intervals the following:
All cables for cuts or damage as well as all connectors for corroded contacts.
The attachment of the cable reel at the end of the boom.
The plunger of the ATB switch for excessive corrosion.
Excessive wear of brushes in the reeling drum.
Evidence of leakage at the pressure transducer connection.
Functionality of the bridging device.
Operation of the lockout relays.
Telescopic Cranes Pressure Sensing
Inspection, Testing & Maintenance
-6-
63
i3500 Maintenance
Instruction Manual