Pressure Sensors
The ain value represents cylinder pressure measured in bits by the pressure
sensor. It can reach a maximum of 4095 bits. The Dr + column is a regulated
D.C. voltage level for the excitation of the pressure sensor and must be close
to 5.00 VDC.
P1 and P2 values indicate the state of proximity sensors (prox 1 and prox 2).
P1 and P2 are used to detect target for the rope direction sensor option, this
option is not available for the telescopic crane pressure sensing, multi-point
version. To know the software version of a pressure sensor or its calibration
state, press
look similar to this:
The line beginning with Ver indicates the software version of the pressure
sensor and its creation date. The next two lines indicate if a sensor has been
calibrated or if the calibration is valid. The scale value must be smaller than 1.0.
5.4

Relays

The information shown for the relay cards is divided into two blocks:
The Relay block represents the individual state of every relay. Value "0"
indicates that the relay coil is energized whereas "1" indicates that it's not
energized. The Inputs block represents the state of the 4 DIN inputs. Value
"0" represents an active input. A maximum of 4 relay cards can be installed.
Telescopic Cranes Pressure Sensing
Sensor
ain
Load 1
1325
Load 2
1109
when load 1 is highlighted. The displayed information will
Ver:
Offset:
Scale:
dr+
p1
4.96
1
4.98
1
Load 1
1.01
07 jun 07
373
0.1421131
53
i3500 Troubleshooting
p2
1
1