4.2 Residual Risks (cont'd)
• The system gives no indication of the presence of power lines in the crane
working area, causing the risk of operating the crane in the proximity of
power lines that could result in injury or death.
• The system gives no indication whether the outriggers have been fully
extended, causing the risk of machine breakage or tipping that could result
in injury or death.
• The system gives no indication of the crane level, causing risk of machine
breakage or tipping that could result in injury or death.
• System gives no indication of poor ground stability causing risk of machine
breakage or tipping that could result in injury or death.
4.3 Power On
Switch on the electric power (i.e.: crane key switch) to the i3500 system. The
indicator will perform a "Self-test" during which time (approx. 10 sec.) the
audible alarm will sound, the approach, overload and motion cut lights will
illuminate and the display will show the RaycoWylie's logo. Subsequently, the
i3500 system goes into normal operating mode as shown in Section 2.1 "i3500
normal mode display" of this manual. The normal mode screen allows you to
visualize the Hook load, Rated capacity, Radius, Boom angle, Hoist used, the
Parts of line, etc.
Telescopic Cranes Pressure Sensing
21
i3500 Operation
Instruction Manual