D) Generic interface board errors
The i3500 system can support up to 4 generic cards: One for wind speed, one
for inclination level, one for absolute rotation and another one for analogical
output. Activation of every generic card is done in the calibration menu
section ''Enable/Disable I/O''.
Error message
Cant x Not Cal
Generic Dr +
Generic
Communication
Load x
Communication
E) Rotation interface board errors
Relative rotation
The i3500 system can support only one (1) rotation card. There are two differ-
ent kinds: a relative one and an absolute one. Activation of rotation card is
done in the calibration menu section ''Enable/Disable I/O''.
Error message
Load encoder cable
Encoder ratio
Encoder prox. position.
Telescopic Cranes Pressure Sensing
Execution process
An appropriate, analogical
sensor is not calibrated
The 5 volts reference voltage
is not valid (if < 4.5 volts or
> 5.5 volts).
The i3500 system does not
receive data from generic card.
If "time out" delay is reached,
then a communication error
is displayed.
The i3500 system does
not receive data from
pressure sensor. If "time
out" delay is reached, then
a communication error is
displayed.
Execution process
A GND wire indicates
that the cable between the
encoder and the rotation
card is not cut. If the cable
breaks, this wire will become
open. Then the rotation card
will send an error message to
the i3500 system
No ratio has been entered.
Proximity is not detected in
configured position by i3500
system.
61
i3500 Troubleshooting
Cause of error
An appropriate, analogical
sensor is not calibrated
1) The Generic card is
defective.
1) The Generic card is
defective.
2) The Can Bus network
cable is broken.
1) The Relay card is
defective
2) The Can Bus network
cable is broken.
Cause of error
1) Replace cable between
encoder and rotation card.
1) Put a different value than 0.
1) The Proximity is defective.