RaycoWylie i3500 Instruction Manual page 58

Rated capacity indicator system for telescopic cranes pressure sensing, multi-point version
Hide thumbs Also See for i3500:
Table of Contents

Advertisement

5.2 Angle/ Lenght Sensor (cont'd)
Press
button when "Angle 1" is highlighted to see the software version of
the angle sensor and it's calibration state. The displayed information will look
similar to this:
The line beginning with "ver" indicates the software version of the angle/length
sensor and also its creation date. The next two lines indicate if a sensor has
been calibrated or if the calibration is valid.
D1gx and d1gy must be close to 820 ±1% .
Dzerox and dzeroy must be close to 2048 ±1%.
Zero angle: is the angle in degrees given by the angle sensor when the zero
of the angle has been calibrated on the machine.
To view the software version of the length sensor or it's calibration state,
press
key when Length 1 is highlighted. The displayed information
will look similar to this:
The line beginning with Ver indicates the software version of the angle/length
sensor and also its creation date. The next two lines indicate if a sensor has
been calibrated or if the calibration is valid. The scale value must be smaller
than 1.0.
Telescopic Cranes Pressure Sensing
Angle 1
ver:
1.01
d1gx:
823.0
dzerox:
2041.0
zero angle: -150.2
Lenght 1
Ver:
1.01
Offset:
Scale:
52
07 jun 07
d1gy: 822.0
dzeroy: 2034.0
07 jun 07
57
0.149661
i3500 Troubleshooting