RaycoWylie i3500 Instruction Manual page 30

Rated capacity indicator system for telescopic cranes pressure sensing, multi-point version
Hide thumbs Also See for i3500:
Table of Contents

Advertisement

4.4.1 Duty Number Selection (cont'd)
Here you can input a specific duty number in the i3500 system. For example, if
you know that the duty number 57 represents your crane rigged with a 100 ft
boom length, outriggers extended and with a 40 ft jib at 10°, it would be more
convenient to enter the number 57 instead of having to choose each correct
parameters individually. Look up the crane duty number to be used on the
i3500 duty list. The currently selected duty number is displayed in the upper
right corner of the display (see Fig. 1, b).
or
or
The duty number is a four digit entry. Add leading zeros (0) before the desired
number as necessary. Example: duty#65 = 0065, duty#8 = 0008.
Telescopic Cranes Pressure Sensing
Changing the crane configuration by
the duty number
1) Press the Duty button (7) to display the duty menu
Note: the duty number should be already highlighted
2) Press Select button (4) to enter the duty
number menu.
3) Press Scroll Up or Down button to highlight the
desired number for the first digit (see fig.1, a)
4) Push Select button (4) to confirm your choice.
5) Scroll Up or Down to highlight the desired
number for the second digit.
6) Press Select button (4) to confirm your choice.
7) Repeat steps 5 and 6 for the last two digits.
24
i3500 Operation
Instruction Manual

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for RaycoWylie i3500

Table of Contents