Warning Lights And Indicators Detailed Description - RaycoWylie i3500 Instruction Manual

Rated capacity indicator system for telescopic cranes pressure sensing, multi-point version
Hide thumbs Also See for i3500:
Table of Contents

Advertisement

2.3 Warning Lights and Indicators Detailed Description
Telescopic Cranes Pressure Sensing
The approach warning light blinks when the load on the
hook is between 90% and 99.9% of the rated capacity
(adjustable value; EN13000:2010: 90% and 97.5% ).
This is accompanied by an audible warning device
that is fitted inside the display unit. This light
(yellow in color) will also flash on and off if you are
approaching within 5 units (feet, meters or degrees) of
a predetermined limit (set in the limits setting mode).
Operate with caution !
The crane is working near its
maximum operating capacity.
The overload warning light (red in color) illuminates at
or above 100% of the rated capacity. This light will also
turn on if you are reaching a predetermined limit (set
in the limits setting mode).
The crane's maximum capacity has
been reached or exceeded.
The motion cut warning light (red in color) illuminates
at or above 100.1% of the rated capacity. This is
usually associated with, for example, booming down,
telescoping out or hoisting up. The exact operation is
specific to the crane model.
The crane has exceeded safe
operational ratings and is now in an
unsafe condition. Hoist up, telescope
out and boom down functions will be
stopped if a motion cut solenoid is
connected to the system.
16
i3500 Introduction
Instruction Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents