4.4.4
System Test
Caution !
The crane must not be in overloading condition when using
the test function.
Telescopic Cranes Pressure Sensing
1) Press Bypass/Rigging (9) and Tare (10) buttons
simultaneously to check the operation of the display,
the audible and visual alarms and the relays
(digital outputs). Some systems will run this test
automatically while others will offer a test menu, if
you see a test menu proceed as follows:
2) Use the Scroll up (2) or Scroll down (3) buttons
to select the function to test.
3) Press Select (4) button to run the desired test. If
the ''button test'' function is selected, press a
button to see its corresponding number appear on
the screen.
To exit the ''button test'' do not press any buttons
and the system will automatically return to the test
menu screen.
4) Press Escape (5) button to exit the test menu.