GD200A series VFD
Function
Name
code
Running time of
P10.11
step 4
Multi-step
P10.12
speed 5
Running time of
P10.13
step 5
Multi-step
P10.14
speed 6
Running time of
P10.15
step 6
Multi-step
P10.16
speed 7
Running time of
P10.17
step 7
Multi-step
P10.18
speed 8
Running time of
P10.19
step 8
Multi-step
P10.20
speed 9
Running time of
P10.21
step 9
Multi-step
P10.22
speed 10
Running time of
P10.23
step 10
Multi-step
P10.24
speed 11
Running time of
P10.25
step 11
Multi-step
P10.26
speed 12
Running time of
P10.27
step 12
Multi-step
P10.28
speed 13
Running time of
P10.29
step 13
Multi-step
P10.30
speed 14
Description
Goodrive200A series VFDs can set 16 steps
speed, selected by the combination of multi-step
terminals 1–4, corresponding to the speed 0 to
speed 15.
Output frequency
Terminal 1
(16)
Terminal 2
(17)
Terminal 3
(18)
Terminal 4
(19)
When terminal1= terminal 2= terminal 3= terminal
4=OFF, the frequency input manner is selected via
or P00.07. When all terminals aren't
code
P00.06
off, it runs at multi-step which takes precedence of
keypad, analog value, high-speed pulse, PLC,
communication frequency input. Select at most 16
steps speed via the combination code of terminal
1, terminal 2, terminal 3, and terminal 4.
The start and stopping of multi-step running is
determined by function code P00.06, the
relationship between
terminal 1 (16), terminal 2 (17), terminal 3 (18),
terminal 4 (19) and multi-step speed is as
following:
Trminal 1
OFF ON
Terminal 2 OFF OFF ON
Terminal 3 OFF OFF OFF OFF ON
Terminal 4 OFF OFF OFF OFF OFF OFF OFF OFF
Step
0
1
Terminal 1 OFF ON
Terminal 2 OFF OFF ON
Terminal 3 OFF OFF OFF OFF ON
Terminal 4 ON
ON
Step
8
9
OFF ON
OFF ON
OFF ON
ON
OFF OFF ON
ON
ON
2
3
4
5
6
OFF ON
OFF ON
OFF ON
ON
OFF OFF ON
ON
ON
ON
ON
ON
ON
ON
10
11
12
13
14
-86-
Function parameters
Default
Modify
value
○
0.0s
○
0.0%
○
0.0s
○
0.0%
○
0.0s
○
0.0%
○
0.0s
○
0.0%
○
0.0s
○
0.0%
○
0.0s
○
0.0%
○
0.0s
○
0.0%
○
0.0s
ON
○
0.0%
ON
○
0.0s
7
○
0.0%
ON
ON
○
0.0s
ON
15
○
0.0%
Need help?
Do you have a question about the Goodrive200A Series and is the answer not in the manual?
Questions and answers
Ou2 fault
An Ou2 fault on the INVT Goodrive200A Series indicates an IGBT Ph-V fault. Possible causes include:
- IGBT module fault
- Misoperation caused by interference
- Poor connection of driving wires
- Improper grounding
To fix it:
- Increase the acceleration time
- Change the power unit
- Check the driving wires
- Inspect external equipment and eliminate interference
- Ensure proper grounding
This answer is automatically generated