Troubleshooting Table - Sega AFTER BURNER CLIMAX Owner's Manual

Hide thumbs Also See for AFTER BURNER CLIMAX:
Table of Contents

Advertisement

1- TROUBLESHOOTING TABLE

If a problem has occurred, first inspect the connection of the wiring connector.
TABLE 17-2
PROBLEMS
When the main SW is
turned ON, the machine
is not activated.
Billboard fluorescent
lamp does not glow.
Sounds are emitted and
the lamps are lit, but the
screen is black.
Sound is not emitted.
CAUSE
The power is not ON.
Incorrect power source/
voltage.
The Circuit Protector of the
AC Unit functioned due to
momentary overcurrent.
The fuse of the fuse holder was
blown out due to momentary
overcurrent.
Faulty connection of
connectors
Fluorescent lamp and glow
lamp need replacement.
Faulty connections for the
visual signal connector or the
monitor power connector.
Broken monitor.
Sound volume adjustment is
not correct.
Faulty connections for various
connectors.
Malfunctioning board,
amplifier and speaker.
Speaker settings are incorrect.
COUNTERMEASURES
Firmly insert the plug into the outlet.
Make sure that the power supply/voltage are
correct.
After eliminating the cause of overload, have the
Circuit Protector of the AC Unit restored. (See
Section 6, 4 , Refer to the following.)
After eliminating the cause of overload, replace
the specified rating fuse. (Photo 17-3)
Join connectors securely between cabinet and
billboard. (See chapter 6-2.)
Replace the fluorescent lamp and the glow lamp.
(See chapter 15.)
Check the connections for the monitor and game
board connectors.
Contact the company from whom the unit was
purchased.
Adjust the switch unit's sound adjustment
volume. (See 9-1.)
Check the connections for the game board, amp,
speakers and volume connectors.
Perform output test and check. (See 9-3b.)
Check the AUDIO OUTPUT setting on the
game setting screen. (See 9-3c.)