Installation Guide Linear Rotary Motors
5.3 Connector Wiring Linear Rotary Motor
Connector wiring
Ph 1+ / Ph A
Ph 1- / Ph B
Ph 2+ / Ph C
Ph 2- / (-)
+5VDC
GND
Sin
Cos
Temp.
Shield
Extension cables are double shielded. The two shields of the extension cables must not be
connected together: the inner shield of the extension cables is used as GROUND and must
be connected to GROUND*; only the outer shield must be connected to SHIELD* of the
connector.