CHAPTER 3 ENGINE
the cap hold the pressure for at least 10
seconds
WARNING: When removing the
radiator cap tester put a rag on the filler
to pre- vent splash of coolant DO NOT
allow a pressure to exceed the radiator
cap re- lease pressure.
WARNING: When removing the
radiator cap tester put a rag on the filler
to pre- vent splash of coolant DO NOT
allow a pressure to exceed the radiator
cap release pressure.
If the pressure drops during 10 seconds,
it indicates that there is leakage with the
cooling system. In this case, check the com-
plete system and replace the leaking parts
or components.
3.4.4
cooling of Radiator and
Water Hoses Radia-tor
Cap
● Remover radiator cap ①
● Install radiator cap to cap tester ②
● slowly increase pressure to 108kPa and
if the cap hold the pressure for at least 10
seconds
● If the cap cannot meet the pressure
requirement, replace it.
Radiator Cap Valve Opening Pressure
Standard: 108kPa