Pr-23-Rp Mounting Specifications; Figure 75 Cfc-Rp-M20-Ss/Hc/Ha-M10-Nc-Pg/Sn/Wp Flow Cell - Vaisala PR-23 Series User Manual

Process refractometer
Hide thumbs Also See for PR-23 Series:
Table of Contents

Advertisement

PR-23 Series User Guide
10.7.6 PR‑23‑RP mounting specifications
The refractometer sensor is installed in the process, either directly by welding a mounting
flange to 2 in or larger pipes or vessels, or using a 1 in, 2 in or 3 in cross flow cell. Due to the
sensor's rugged, innovative non-weld sensor body, and self‑cleaning or optional wash
system capabilities, the PR‑23‑RP functions accurately and reliably in harsh refinery
conditions. Intrinsically safe and hazardous area certification is provided for hazardous
areas.
PR‑23‑RP mounting in CFC 1 in line
Item.
Descrip�on
1
Sensor PR-23-RP-73-M20
2
CFC-RP-M20-M10-NC-PG/SN/WP
3
2"ANSI 300 Wash nozzle
4
1"ANSI 300 blind flange
Figure 75 CFC‑RP‑M20‑SS/HC/HA‑M10‑NC‑PG/SN/WP flow cell
144
Supplied by
Pcs.
Item.
Vaisala
1
5
Vaisala
1
6
Vaisala
1
7
Vaisala
1
8
9
Descrip�on
Supplied by
Bolt, washer and nut for 1"flange
Customer
1'' flange gasket
Customer
2'' flange gasket
Customer
1'' ANSI 300 Welding neck flange
Customer
Bolt, washer and nut for 2"flange
Customer
IM-EN-PR23-E
Pcs.
8
2
3
2
16

Advertisement

Table of Contents
loading

Table of Contents