Vaisala K‑PATENTS PR-43-AC User Manual

Vaisala K‑PATENTS PR-43-AC User Manual

Sanitary process refractometer
Table of Contents

Advertisement

Quick Links

M212438EN-C
User Guide
Sanitary Process Refractometer
PR-43-AC/AP

Advertisement

Table of Contents
loading

Summary of Contents for Vaisala K‑PATENTS PR-43-AC

  • Page 1 M212438EN-C User Guide Sanitary Process Refractometer PR-43-AC/AP...
  • Page 2 English versions are This product contains software developed applicable, not the translations. by Vaisala or third parties. Use of the The contents of this document are subject software is governed by license terms and to change without prior notice.
  • Page 3: Table Of Contents

    Version information..................5 Related manuals....................5 Documentation conventions................5 Trademarks......................6 Product overview.................... 7 Vaisala Sanitary Process Refractometers PR‑43‑AC and PR‑43‑AP...7 Safety........................7 Installation......................9 Choosing mounting location................9 Checklist for pipe mounting................9 Checklist for mounting in tank, vessel or large pipe........10 Mounting guide....................11...
  • Page 4 PR-43-AC/AP User Guide M212438EN-C Appendix B: PR-43 refractometer verification form......62 Appendix C: EU declaration of conformity..........63 Warranty......................65 Technical support.................... 65 Recycling......................65...
  • Page 5 List of figures List of figures Figure Refractometer models..................7 Figure 2 PR-43-AC and PR-43-AP mounting guide..........11 Figure 3 The M12 connector................... 12 Figure 4 Connecting refractometer cable to refractometer......... 13 Figure 5 Wiring with analogue output only.............. 13 Figure 6 Wiring options with both analogue and digital outputs......
  • Page 6 PR-43-AC/AP User Guide M212438EN-C List of tables Table Document versions (English)................5 Table 2 Related manuals....................5 Table 3 Wash medium parameters for integral wash nozzles in PR-43-AP..17 Table 4 Wash medium parameters for flowcell wash nozzle AFC.......17 Table 5 Flowcell -H10 or -H15..................23 Table 6 Flowcell -H20 or -H25..................
  • Page 7: About This Document

    This document provides instructions for installing and using the Vaisala K‑PATENTS® Sanitary Process Refractometers PR‑43‑AC and PR‑43‑AP. This product manual is delivered to the end user with a Vaisala K‑PATENTS® product. Information in this manual is subject to change without notice. When the manual is changed, a revised copy is published at www.kpatents.com.
  • Page 8: Trademarks

    Indicates that you need to take some notes during the task. 1.4 Trademarks Vaisalaâ and K-PATENTS® are registered trademarks of Vaisala Oyj. Linuxâ is a registered trademark of Linus Torvalds. Windowsâ is either a registered trademark or trademark of Microsoft Corporation in the United States and other countries.
  • Page 9: Product Overview

    Chapter 2 – Product overview 2. Product overview 2.1 Vaisala Sanitary Process Refractometers PR‑43‑AC and PR‑43‑AP The sanitary refractometers PR‑43‑AC and PR‑43‑AP provide a digital interface detection system for alimentary industry. The PR‑43‑AC/AP measures the refractive index n and the temperature of the process medium.
  • Page 10 PR-43-AC/AP User Guide M212438EN-C The process medium may be hot or otherwise hazardous. Use shields and protective clothing adequate for the process medium. Do not rely on avoidance of contact with the process medium. Wear protective eyewear. Wear protective gloves. Precautions when removing a sensor from the process line : •...
  • Page 11: Installation

    If the process pipe vibrates, support the pipe. A vibrating pipe might damage the inline refractometer mounted on it. A Vaisala K‑PATENTSâ inline refractometer can be located either indoors or outdoors in most climates. However, when a refractometer is located outdoors, some basic protection against direct exposure to sunlight and rain should be provided.
  • Page 12: Checklist For Mounting In Tank, Vessel Or Large Pipe

    PR-43-AC/AP User Guide M212438EN-C • If the refractometer is used in a feed-back control loop, make the time lag short. E.g. when a dilution valve is controlled, mount the refractometer close to the dilution point. However, make sure complete mixing has occurred at mounting location. •...
  • Page 13: Mounting Guide

    Chapter 3 – Installation 3.4 Mounting guide Figure 2 PR-43-AC and PR-43-AP mounting guide...
  • Page 14: Electrical Connections

    PR-43-AC/AP User Guide M212438EN-C 3.5 Electrical connections The refractometer has an M12 connector in the refractometer for power supply, mA output and Ethernet connections. Figure 3 The M12 connector PR-43 refractometers are powered with 24 VDC. For connecting the refractometer to Multichannel user interface MI, see the Instruction manual for Multichannel User Interface MI. For connecting the refractometer to Compact user interface CI, see the Instruction manual for Compact User Interface CI.
  • Page 15: Figure 4 Connecting Refractometer Cable To Refractometer

    Chapter 3 – Installation Turn to tighten Align groove and Connector screw thread guide P4-031 Figure 4 Connecting refractometer cable to refractometer The PR-43 refractometer provides both analog (mA) and digital output signals. See the following figure for the wiring when only analog output is used. PR-43 REFRACTOMETER M-12-8 pin, A-code, M non-Ex...
  • Page 16: Figure 6 Wiring Options With Both Analogue And Digital Outputs

    PR-43-AC/AP User Guide M212438EN-C PR-43 REFRACTOMETER M-12-8 pin, A-code, M PR-8431 non-Ex Split cable M12 M12-8 pin, A-code, F Ethernet (M12-4 pin, D-code,M) mA, 24V 10m (33ft) 10m (33ft) PR-43 REFRACTOMETER PR-8431 M-12-8 pin, A-code, M Split cable M12 non-Ex M12-8 pin, A-code, F Ethernet (M12-4 pin, D-code,M) mA, 24V...
  • Page 17: Figure 8 Connections In M12 And Rj-45 Connectors

    Chapter 3 – Installation Figure 8 Connections in M12 and RJ-45 connectors In split cables the power cable and the mA output cable are marked near the end of the cable. Power cable: • White: +24DC • Brown: GND mA output cable: •...
  • Page 18: Prism Wash

    PR-43-AC/AP User Guide M212438EN-C 4. Prism wash Prism wash requires a system for wash control and diagnostics. This can be achieved with Multichannel user interface (MI) with a relay module. 4.1 Prism coating Deposit build-up on the prism surface disturbs the measurement. Anabnormally high concentration reading, an upward concentration (CONC) drift, decreased QF value or increased LED value may indicate coating.
  • Page 19: Recommended Wash Pressures And Times

    Chapter 4 – Prism wash 4.2.1 Recommended wash pressures and times The following tables provide the recommended wash pressures and times. Table 3 Wash medium parameters for integral wash nozzles in PR-43-AP Minimum above Maximum above Wash Recover Interval process pressure process pressure time Steam (SN) 2 bar (30 psi)
  • Page 20: Prism Wash Systems

    PR-43-AC/AP User Guide M212438EN-C 4.2.2 Prism wash systems WARNING! In high pressure wash systems, pressure increase can occur in a closed pipe section when the high pressure pump is operated. It is recommended to mount a pressure relief valve in the pipe section. Relief pressure should be according to pipe pressure rating.
  • Page 21: Figure 9 Prism Wash System For Steam

    Chapter 4 – Prism wash Figure 9 Prism wash system for steam...
  • Page 22: Figure 10 Wiring For Prism Wash System For Steam

    PR-43-AC/AP User Guide M212438EN-C PR-43 REFRACTOMETER (1-4 pcs.) MULTI CHANNEL USER INTERFACE MI 3894 PR-8430 Platform 4 cable RELAY OUTPUT mA-OUTPUT MODULE MODULE PR-50023 PR-50021 SAFETY SWITCH PR-7060 RELAY RELAY + 1 - + 2 - OPTIONAL 24V POWER SUPPLY FOR MI 2122 2324 1 2 3 4 5...
  • Page 23: Figure 11 Prism Wash System For High Pressure Water

    Chapter 4 – Prism wash 3892 Water supply min 10l/min( 2.5gal/min) Max temp. 60°C (140°F). Safe water for sanitary use. No. Descrip�on Supplied by Qty 1 PR-43 refractometer K-Patents 2 Mul�channel user interface K-Patents 3 Power relay unit PR_3603-300-U/M-230/110 K-Patents 4 Pla�orm 4 cable PR-8430 K-Patents 5 Relay cable 3x1 (AWG 17)
  • Page 24: Prism Wash Nozzles

    PR-43-AC/AP User Guide M212438EN-C PR-43 REFRACTOMETER (1-4 pcs.) MULTI CHANNEL USER INTERFACE MI 3894 RELAY MODULE mA-OUTPUT MODULE POWER RELAY UNIT PR-50023 PR-50021 MAINS PR-3603-____ SWITCH RELAY RELAY + 1 - + 2 - THERMAL OPTIONAL 24V POWER T1T2T3 OVERLOAD SUPPLY FOR MI RELAY T1T2...
  • Page 25: Table 5 Flowcell -H10 Or -H15

    Chapter 4 – Prism wash Table 5 Flowcell -H10 or -H15 Part number Steam 64.75 PR-3365 Water PR-3369 Pressurized water PR-3368 Table 6 Flowcell -H20 or -H25 Part number Steam 72.15 PR-3375 Water PR-3379 Pressurized water PR-3378 Table 7 Flowcell -H30 Part number Steam PR-3393 Water...
  • Page 26: Figure 14 Process Connection Of Wash Nozzle In Flowcell

    PR-43-AC/AP User Guide M212438EN-C Figure 14 Process connection of wash nozzle in flowcell For PR-43-AP, select the wash nozzle according to wash medium, see the following table. Table 9 Prism wash nozzle selection PR-43-AP Steam nozzle PR-9321 Water nozzle PR-9320 Pressurized water nozzle PR-9322...
  • Page 27: Technical Data

    Chapter 5 – Technical data 5. Technical data 5.1 Compatibility Electrically: The PR-43 refractometers are not interchangeable with any other refractometer model. All PR-43-AC/AP refractometers are however interchangeable with each other as long as they have the same prism. The PR-43-AC/AP refractometers are not compatible with the indicating transmitters DTR, STR or IT-R.
  • Page 28: Pr-43-Ac Model Code

    PR-43-AC/AP User Guide M212438EN-C Figure 16 PR-43-AC dimensions 5.3.1 PR-43-AC model code The following table lists the model codes for the sanitary compact refractometer for pipelines.
  • Page 29: Table 10 Sanitary Compact Refractometer For Pipelines

    Chapter 5 – Technical data Table 10 Sanitary compact refractometer for pipelines Model and description Model PR-43 = Refractometer PR-43 Refractometer model -AC = Compact sanitary certified process refractometer, insertion length 14 mm -AC Prism material and Refractive Index range limit -73 = R.I.
  • Page 30: Pr-43-Ac Mounting Hardware Model Code

    PR-43-AC/AP User Guide M212438EN-C 5.3.2 PR-43-AC mounting hardware model code The following tables list the model codes for the sanitary compact refractometer mounting hardware. Table 11 Mounting hardware without wash nozzles Model and description Model AFC = Elbow flow cell Refractometer connection -H = Sanitary 3A clamp, 2 1/2 in Construction material SS = AISI 316...
  • Page 31: Table 13 Mounting Hardware With Wash Nozzles

    Chapter 5 – Technical data Model and description Model -SI = Straight pipe EHEDG -EH = EHEDG Type EL Class I Certified model Polishing option -EP = Electropolished process wetted parts (Ra 0.4 µm, 15 µ in) For EHEDG certified refractometers use ISO2852 type EHEDG certified gasket PR-9202-EH (2½...
  • Page 32: Table 14 Mounting Hardware, Mini Flow Cell

    PR-43-AC/AP User Guide M212438EN-C Model and description Model -WN = Water nozzle, threads G ¼ in female -WP = Pressurized water nozzle, threads G ¼ in female -PG = Plug for nozzle connection With -SI option only Example: • Refractometer: PR-43-AC-73-H25-P15 •...
  • Page 33: Table 16 Mounting Hardware

    Chapter 5 – Technical data Model and description Model • 40 = 100 mm (4 in) • -40 • 50 = 50 mm (2 in) • -50 • 65 = 65 mm (2.5 in) • -65 • 80 = 80 mm (3 in) •...
  • Page 34: Pr-43-Ac Specifications

    PR-43-AC/AP User Guide M212438EN-C 5.3.3 PR-43-AC specifications The following table lists the standard and optional specifications for the PR-43-AC refractometer. Table 17 PR-43-AC specifications Standard Optional REFRACTOMETER PR-43-A PR-43-AC Compact model for small pipelines. Models Refractive Index range Full range, n = 1.3200 … 1.5300 1.2600 …...
  • Page 35 Chapter 5 – Technical data Standard Optional Process wetted parts AISI 316L stainless steel, prism Alloy C276 sapphire, prism gasket modified PTFE (Teflon), gasket EPDM for Sanitary 3‑A and ISO2852 type EHEDG certified gasket for EHEDG certified refractometers. Refractometer protection IP67, Type 4X class Refractometer weight...
  • Page 36: Pr-43-Ac Parts List

    PR-43-AC/AP User Guide M212438EN-C 5.3.4 PR-43-AC parts list Figure 17 Refractometer cover assembly Table 18 Refractometer cover assembly parts list Item Description Part number Quantity Screw M4x10 DIN7380 Torx PR-14003 tamper proof PR-43 end plate PR-14001 Dryer pack PR-9108 PR-43 sensor interface card PR-43 interface card (Ex ia) PR-50011 mA-output card (general...
  • Page 37 Chapter 5 – Technical data Item Description Part number Quantity PR-43 sensor processor card Ex processor card (Ex ia) PR-50012 General purpose and Ex nA PR-50038 Screw M3x10 DIN965 TX A2 PR-33/PR-43-A card holder PR-14050 PR-33/PR-43-A disk spring ring Screw M5x10 ISO 14583 TX A2 Nord-Lock washer NL5ss PR-43 connector &...
  • Page 38: Figure 18 Pr-43-Ac Assembly

    PR-43-AC/AP User Guide M212438EN-C Figure 18 PR-43-AC assembly Table 19 PR-43-AC assembly parts list Item Description Part number Quantity PR-43-AC nameplate PR-14404 PR-43 base assembly PR-43 compact core H73 Optics module PR-14020 H74 Optics module PR-14022 Sensor head PR-43-AC-H25-SS head PR-10001 PR-43-AC-E25-SS head PR-10028 PR-43-AC-H25-HC head PR-10001-HC...
  • Page 39: Pr-43-Ac Mounting Specifics

    Chapter 5 – Technical data 5.3.5 PR-43-AC mounting specifics Sanitary process refractometer PR-43-AC is connected to the process by a 2 1/2" 3A sanitary clamp. The recommended mounting is in a pipe bend, with a vertical flow upwardsbefore the refractometer, and a horizontal pipe after. This mounting ensures 1.
  • Page 40: Figure 20 Flow Cell Afc-Hss-H10 For Pipe Diameter 25 Mm (1 In) And H15 For Pipe Diameter 40 Mm (1.5 In)

    PR-43-AC/AP User Guide M212438EN-C For smaller pipe diameters, flow cells are available, see the following figures. The flow cells are exchangeable with standard 90° bend pieces. Figure 20 Flow cell AFC-HSS-H10 for pipe diameter 25 mm (1 in) and H15 for pipe diameter 40 mm (1.5 in)
  • Page 41: Figure 21 Flow Cell Afc-Hss- With Wash Nozzle Connection (-Nc)

    Chapter 5 – Technical data Figure 21 Flow cell AFC-HSS- with wash nozzle connection (-NC) H10 for pipe diameter 25 mm (1 in) and H15 for pipe diameter 40 mm (1.5 in)
  • Page 42: Figure 22 Flow Cell Afc-Hss-H20 For Pipe Diameter 50 Mm (2 In)

    PR-43-AC/AP User Guide M212438EN-C SECTION A-A SCALE 1 : 2 Flow cell type 48.6 51.6 89.0 AFC-HSS-H20-SI 48.6 48.6 51.6 89.0 AFC-HSS-H20-RI 35.6 60.3 64.1 108.0 AFC-HSS-H25-SI 60.3 Figure 22 Flow cell AFC-HSS-H20 for pipe diameter 50 mm (2 in) and H25 for pipe diameter 65 mm (2.5 in)
  • Page 43: Figure 23 Flow Cell Afc-Hss- With Wash Nozzle Connection (-Nc) H20 For Pipe Diameter 50 Mm (2 In) And H25 For Pipe Diameter 65 Mm (2.5 In)

    Chapter 5 – Technical data SECTION A-A SCALE 1 : 2 Flow cell type 45° AFC-HSS-H20-SI-NC 48.6 48.6 51.6 89.0 48.6 51.6 89.0 AFC-HSS-H20-RI-NC 35.6 60.3 64.1 108.0 AFC-HSS-H25-SI-NC 60.3 SECTION B-B SCALE 1 : 5 Figure 23 Flow cell AFC-HSS- with wash nozzle connection (-NC) H20 for pipe diameter 50 mm (2 in) and H25 for pipe diameter 65 mm (2.5 in)
  • Page 44: Figure 24 Side Flow Cells

    PR-43-AC/AP User Guide M212438EN-C Figure 24 Side flow cells Sanitary Refractometer PR-43-AC-Z is mounted using 3-A Sanitary certified 2.5 in CherryBurrell I-Line fittings that are made of interlocking flat face ferrules, a flat gasket and a clamp. This interlocking, metal-to-metal design eliminates over compression by the clamp not allowing the gasket to be extruded into the product contact side.
  • Page 45: Figure 25 I-Line Fitting For Pr-43-Ac

    Chapter 5 – Technical data Refractometer wetted parts material is AISI 316L or Alloy C, gaskets EPDM. Figure 25 I-Line fitting for PR-43-AC Table 20 I-Line fitting for PR-43-AC Item Name Material Supplied by Quantity Refactometer PR-43- AISI616L K‑Patents AC-Z25 65 mm (2.5 in) I-clamp AISI304 Customer 65 mm (2.5 in) I-clamp...
  • Page 46: Mounting Specifics For Ehedg Certified Pr-43-Ac Configuration

    Such surfaces may not stay clean in processing. Vaisala offers a 3-A Sanitary Standard Accepted repair and maintenance package in which all wetted parts, prism, gaskets and dryer are replaced.
  • Page 47: Figure 26 Mounting With Sanitary Ferrule, Pipe Diameter 80 Mm (3 In) Or More Ehedg Certified Configuration

    Chapter 5 – Technical data TYPE EL CLASS I November 2015 Figure 26 Mounting with sanitary ferrule, pipe diameter 80 mm (3 in) or more EHEDG certified configuration The following table lists the parts in the figure above and the materials of the mounting hardware.
  • Page 48: Sanitary Process Refractometer Pr-43-Ap

    PR-43-AC/AP User Guide M212438EN-C Number Item Material Quantity Sanitary gasket 65 mm (2.5 in) ISO2852 type EHEDG certified 5.4 Sanitary process refractometer PR-43-AP Sanitary probe refractometer PR-43-AP provides an accurate in-line Brix measurement in cookers, tanks and large pipelines. The PR-43-APT refractometer version can be installed through an APV Tank bottom flange.
  • Page 49: Pr-43-Ap Model Code

    Chapter 5 – Technical data Figure 28 Flush mounted refractometer PR-43-AP-T10-L00 5.4.1 PR-43-AP model code The following table lists the model codes for the sanitary probe refractometer for large pipelines and vessels. Table 22 SANITARY PROBE REFRACTOMETER for large pipelines and vessels Model and description Model PR-43 = Refractometer PR-43...
  • Page 50 PR-43-AC/AP User Guide M212438EN-C Model and description Model -Z25-P15 = 63.5 mm (2.5 in) I-clamp, 15 bar -Z25-P15 Insertion length, models H25-P15/P40 -L14 1) 2) -L14 = insertion length 14 mm (0.55 in) -L42 1) 2) -L42 = insertion length 42 mm (1.65 in) -L140 -L140 = insertion length 140 mm (5.5 in) -L170...
  • Page 51: Pr-43-Ap Mounting Hardware Model Code

    Chapter 5 – Technical data For models with EHEDG certified versions available Table 23 SANITARY PROBE REFRACTOMETER with prism wash for large pipelines and vessels Model and description Model PR-43 = Refractometer PR-43 Refractometer model -AP = Sanitary process refractometer, probe Prism material and Refractive Index range limit -73 = R.I.
  • Page 52: Pr-43-Ap Specifications

    PR-43-AC/AP User Guide M212438EN-C Table 24 Mounting hardware for PR-43-AP refractometer Part number and description Model VFMA-T10 = MT4 DN25/1T APV tank bottom flange for PR-43-AP T10 VFMA-T10 VFBP-T10 = blind flange for MT4 DN25/1T APV tank bottom flange VFBP-T10 VFME-V25 = mount adaptor for PR-43-AP V25 HEXNUT type VFME-V25 VFMF-V25 = mount adaptor for PR-43-AP V25 HEXNUT extended VFMF-V25...
  • Page 53 Chapter 5 – Technical data REFRACTOMETER PR-43-A PR-43-AP probe model for large pipelines and vessels Models Hygienic design certification 3-A Sanitary Standard 46-04 certified and EHEDG (European Hygienic Engineering & Design Group) Type EL Class I certified. Process pressure Sanitary 3A and I-clamp max. 15 bar (200 psi) at 20 °C (70 °F)/ 9 bar (125 psi) at 120 °C (250 °F).
  • Page 54: Pr-43-Ap Parts Lists

    PR-43-AC/AP User Guide M212438EN-C 5.4.4 PR-43-AP parts lists Figure 29 Refractometer cover assembly Table 26 Refractometer cover assembly parts list Item Description Part number Quantity Screw M4x10 DIN7380 Torx PR-14003 tamper proof PR-43 end plate PR-14001 Dryer pack PR-9108 PR-43 sensor interface card PR-43 interface card (Ex ia) PR-50011 mA-output card (general...
  • Page 55 Chapter 5 – Technical data Item Description Part number Quantity PR-43 sensor processor card Ex processor card (Ex ia) PR-50012 General purpose and Ex nA PR-50038 Screw M3x10 DIN965 TX A2 PR-33/PR-43-A card holder PR-14050 PR-33/PR-43-A disk spring ring Screw M5x10 ISO 14583 TX A2 Nord-Lock washer NL5ss PR-43 connector &...
  • Page 56: Figure 30 Pr-43-Ap Assembly

    PR-43-AC/AP User Guide M212438EN-C Figure 30 PR-43-AP assembly Table 27 PR-43-AP assembly parts list Item Description Part Quantity Product code number PR-43-AP name plate PR-43-base assembly HX3 core assembly PR-14021 Sensor head PR-23-AP-PSS head PR-10006 PR-43-AP-T10-P15-L00 PR-23-AP-RSS head PR-10007 PR-43-AP-H40-L170 PR-23-AP-TSS head PR-10008 PR-43-AP-H25-L170 PR-23-AP-RSS-NC head...
  • Page 57: Pr-43-Ap Mounting Specifics

    Chapter 5 – Technical data Item Description Part Quantity Product code number PR-23-AP-QSS head PR-10018 PR-43-AP-H25-L140 PR-23-AP-SSS head PR-10024 PR-43-AP-H40-L63 PR-23-AP-ISS head PR-10025 PR-43-AP-H25-L42 PR-23-AP-BSS head PR-10026 PR-43-AP-T10-L170 4.10 PR-23-AP-HSS head PR-10027 PR-43-AP-H25-L14 4.11 PR-23-AP-CSS head PR-10029 PR-43-AP-E25-L170 (DN65 Varivent head) 4.12 PR-23-AP-ZP head PR-10046...
  • Page 58: Figure 31 Insertion Of Probe Refractometer Pr-43-Ap-H25

    PR-43-AC/AP User Guide M212438EN-C Figure 31 Insertion of probe refractometer PR-43-AP-H25 The refractometer type PR-43-AP-T10-L00 is flush mounted using a sanitary APV tank bottomflange. The refractometer can be flush mounted in the side wall, which allows the use of a scraper. It is also easily installed through a steam jacket.
  • Page 59: Figure 32 Flush Mounting Probe Refractometer Pr-43-Ap-T10-L100

    Chapter 5 – Technical data Figure 32 Flush mounting probe refractometer PR-43-AP-T10-L100 Sanitary Refractometer PR-43-AP-Z is mounted using 3-A Sanitary certified 63.5 mm (2.5 in) CherryBurrell I-Line fittings that are made of interlocking flat face ferrules, a flat gasket and a clamp.
  • Page 60: Mounting Specifics For Ehedg Certified Pr-43-Ap Configuration

    5.4.6 Mounting specifics for EHEDG certified PR-43-AP configuration Vaisala offers certain PR-43-AP configurations which have been certified to fulfill the sanitary requirements published by EHEDG (European Hygienic Engineering & Design Group) organization. During this certification the hygienic characteristics of both the refractometer and the process connection were evaluated against the applicable requirements.
  • Page 61: 3-A Sanitary Standard Compliance

    Such surfaces may not stay clean in processing. Vaisala offers a 3-A Sanitary Standard accepted repair and maintenance package in which all wetted parts, prism, gaskets and dryer are replaced.
  • Page 62: Appendix A: Refractometer Verification

    PR-43 is ± 0.0002, then the representative level is the sum of the two accuracy specifications, that is, ± 0.0004. Vaisala provides a set of standard R.I. liquids, PR-2300, containing these five liquids. The set can be ordered directly from Vaisala or through your representative.
  • Page 63 The refractometer serial number is shown in the upper right corner of each display. The list of CCD and TEMP values are found on the Verification results display. Send the form to your Vaisala K-PATENTS® representative or email the collected data to helpdesk@vaisala.com...
  • Page 64: Appendix B: Pr-43 Refractometer Verification Form

    PR-43-AC/AP User Guide M212438EN-C Appendix B. PR-43 refractometer verification form Fill in this form and email it to helpdesk@vaisala.com or to your local service representative. Refractometer serial no: Customer: Address: Fax: Email: Date: Verification made by: Table 28 Verification results display Sample...
  • Page 65: Appendix C: Eu Declaration Of Conformity

    – Part 1: General requirements EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use – EMC requirements – intended for use in industrial locations Signed for and on behalf of Vaisala Oyj, in Vantaa, on 1 September 2019 ______________________________________ Jukka Lyömiö...
  • Page 67: Warranty

    Please see the applicable supply contract or Conditions of Sale for details of the warranty for each product. Technical support Contact Vaisala technical support at helpdesk@vaisala.com. Provide at least the following supporting information as applicable: • Product name, model, and serial number •...
  • Page 70 www. v aisala.com...

This manual is also suitable for:

K‑patents pr-43-ap

Table of Contents