 If auto regeneration did not complete, an aftertreatment
device regeneration request will blink on the monitor. (Refer
to the page 1-34) Perform manual regeneration following
the specified procedure. (Refer to the page 1-35)
 When the machine is operated without performing manual
regeneration, the aftertreatment device may be damaged.
Immediately move the machine to a safe area and perform
manual regeneration.
 Both auto and manual regenerations restore
aftertreatment device function. It is not a malfunction.
 White smoke may be emitted for several minutes after the
engine starts, this is not a malfunction.