4. Rotate selector knob (2) to highlight Aftertreatment
Device Regeneration Inhibited (6).
5. Press selector knob (2) to display Aftertreatment Device
Regeneration Inhibited screen (7).
6. Rotate selector knob (2) to highlight
selector knob (2) to display Aftertreatment Device
Regeneration Inhibited screen (9).
7. Rotate selector knob (2) to highlight ON (10).
Confirmation screen is added.
Press selector knob (2) to turn Aftertreatment Device
Regeneration Inhibited ON. Press selector knob (2) again
to turn Aftertreatment Device Regeneration Inhibited
OFF.
When ON is selected, regeneration inhibited icon (11)
will be displayed on the monitor.
f
NOTE: When the function is ON, the mark "" is displayed in
green. When the function is OFF, the mark "" is displayed in
gray.
IMPORTANT: When the machine is operated with the
aftertreatment device regeneration inhibited, the
aftertreatment device becomes clogged. When
the aftertreatment device regeneration request
is displayed, move the machine to a safe place.
Perform the manual regeneration following the
specified procedure. Failure to do so may damage
the aftertreatment device. Refer to "Aftertreatment
Device" section for the manual regeneration.
OPERATOR'S STATION
(8), and press
1-58
2
11
MNEC-01-006
6
MNEK-01-170EN
7
8
MNEK-01-171EN
9
10
MNEK-01-172EN