Function „Cycle Stroke Color S3/S4 Different; Resetting The Device (Device Reset) - Pentair SUDMO IntelliTop 2.0 Operating Instructions Manual

Control head
Table of Contents

Advertisement

6.8.4.
Function „Cycle stroke color S3/S4 different"
Factory setting of this function:
To make the position feedback of S3 and S4 more clearly distinguishable than only in the flashing frequency,
the "cycle stroke color S3/S4 different" function can be selected via the PC software. This function reports the
position of S3 and S4 in different colors but with the same flashing frequency (250 ms ON / 250 ms OFF).
Details on color coding for this function can be found in chapter "17.1.2. Color combinations with active function
„cycle stroke color S3/S4 different"" on page 85.
6.9.

Resetting the device (Device Reset)

The device can be reset to factory settings directly on the control head or by the PC software.
Procedure - Device Reset directly on the control head:
Simultaneously actuate T1 + T2 + T3 (approx. 2.5 s long) - to access "Device Reset" mode - the corresponding
flashing pattern is: always alternating 500 ms RED, 500 ms GREEN. If the device is not reset 10 s after switching
to "Device Reset" mode, this mode is automatically left.
Simultaneously actuate T1 + T2 + T3 again (approx. 2.5 s long) - this will reset the device. The flashing pattern
250 ms ON / 250 ms OFF in the fault color indicates that the device was reset.
Procedure - Device Reset using PC software:
To do this, select the "General start-up" submenu in the "SYSTEM" main menu and press the "DEV RESET"
button (see also PC software manual).
Device Reset resets the following values to the factory setting:
• Teach positions S1...S3
• Feedback fields from S1...S3
• Resettable switching cycle counters V1...V3
• Resettable operating duration
• Service intervals switching cycles V1...V3
• Service interval operating duration
• Service/maintenance notification (signaling
of elapsed maintenance intervals)
• Manual control function
• Monitoring with external initiator S4 whether
upper valve disc has been closed
• Feedback external initiator S4 as S1
• All valves can be actuated (simultaneously)
28
not active
all positions "not taught"
(see Chapter "6.8.1" on page 26)
(see Chapter "6.8.2" on page 27)
(see Chapter "6.8.2" on page 27)
(see Chapter "6.8.2" on page 27)
(see Chapter "6.8.2" on page 27)
not active (see Chapter "6.8.2" on page 27)
active (see Chapter "6.8.3" on page 27)
(see Chapter "17.3" on page 87, example 2)
not active (see "PC software" manual)
not active (see "PC software" manual, but setting has no function
for the model for double-acting actuators - see Chapter "15" on
page 76)