Factory Settings In The Firmware; Feedback Fields (Position Measuring System) - Pentair SUDMO IntelliTop 2.0 Operating Instructions Manual

Control head
Table of Contents

Advertisement

6.8.

Factory settings in the firmware

The service interface may only be used in non-explosive atmosphere.
The control head is supplied with the following factory settings of the firmware:
6.8.1.

Feedback fields (position measuring system)

A feedback field is the area within which a position (e.g. S1) is reported back.
Signal
Factory setting
S1
S2
S3
(Reference:
Target
upper edge of
the target)
Fig. 9:
Schematic diagram of the feedback fields in the example of the position S1 (not to scale)
Overlaps of S1/S2/S3 are possible (see Chapter "17.3. Signal priorities").
The factory settings for the feedback fields can be changed by the PC software for the IntelliTop 2.0 or by
the "Feedback Field Mode" (see Chapter "16.3. Changing the feedback field - Feedback Field Mode (FFM)" on
page 83) or by the Autotune function 6 (see Chapter "16.2.2. Autotune functions" on page 79).
26
Feedback field at top (positive)
Adjustment range
[mm]
+ 3.00
+ 12.00 ... + 0.50
+ 3.00
+ 12.00 ... + 0.50
+ 1.00
+ 12.00 ... + 0.50
Stroke
Feedback
[mm]
field S1 [mm]
english
Feedback field at bottom (negative)
Factory setting
[mm]
[mm]
- 3.00
- 3.00
- 1.00
Ensure that the teach points including
their feedback fields are within the
measuring range.
Technical Data
Adjustment range
[mm]
- 0.50 ... - 12.00
- 0.50 ... - 12.00
- 0.50 ... - 12.00