Safety Instructions - Pentair SUDMO IntelliTop 2.0 Operating Instructions Manual

Control head
Table of Contents

Advertisement

AS Interface - Design
Calculation examples:
Example 1:
3 valves are activated simultaneously, one position is reported (state for 200 ms):
P
=
P
Slave
El
4.1 W
=
1.0 W
or
I
=
I
Slave
El
136 mA =
33 mA
Example 2:
3 valves have been activated simultaneously, one position is reported (persistent state):
P
=
P
Slave
El
3.8 W
=
1.0 W
or
I
=
I
Slave
El
126 mA =
33 mA
When using an external initiator, its power requirement should be added.
11.6.

Safety instructions

DANGER!
Danger of explosion in explosive atmosphere (only in the event of a fault as zone 2)!
• Opening the hood or the housing in an explosive atmosphere is only allowed in a not energized state!
WARNING!
Risk of injury due to electric shock!
• Before reaching into the system (except for the Teach-In procedure in a non-explosive atmosphere) switch off
the power supply and secure it to prevent restarting!
• Observe applicable accident prevention and safety regulations for electrical equipment!
Risk of injury from improper
• Installation may be carried out by authorized technicians only and with the appropriate tools!
Risk of injury from unintentional activation of the system and uncontrolled restart!
• Secure system against unintentional activation.
• Following installation, ensure a controlled restart.
+ 1 x P
+ 2 x P
Valve-ON
+ 1 x 0.9 W
+ 2 x 0.6 W
+ 1 x I
+ 2 x I
Valve-ON
+ 1 x 30 mA
+ 2 x 20 mA
+ 3 x P
+ 1 x P
Valve
+ 3 x 0.6 W
+ 1 x 1.0 W
+ 3 x I
+ 1 x I
Valve
+ 3 x 20 mA
+ 1 x 33 mA
installation!
+ 1 x P
Valve
LED
+ 1 x 1.0 W
+ 1 x I
Valve
LED
+ 1 x 33 mA
LED
LED
english
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2307193

Table of Contents