Programming Data - Pentair SUDMO IntelliTop 2.0 Operating Instructions Manual

Control head
Table of Contents

Advertisement

11.8.

Programming data

The control heads have been configured as AS interface version with an extended address range (A/B slaves) for
62 slaves or optionally as an AS interface version for 31 slaves.
A change between the two configurations in the control head is only possibly by exchanging the elec-
tronic PCB!
If one control head is replaced with another control head having a different configuration in the AS interface
field bus system (e.g. AS interface version 62 slaves (A/B-Slave) to replace a device with AS interface version
31 slaves), a configuration error will be generated at the master due to the different ID codes!
In this case (intentional replacement!), the current configuration must be re-projected in the AS interface
master. Please read the operating instructions of the used AS interface master!
Factory setting AS-i address:
AS-i address = 0
Programming Data Table
I/O configuration
ID code
Extended ID code 1
Extended ID code 2
Profile
Bit configuration table
Data bit
Input
Output
Parameter bit
Output
54
Programming data for 62 Slaves
AS interface - Device for A/B slave
addressing (default device)
7 hex (4 inputs / 4 outputs)
see below: Bit configuration table
A hex
7 hex
E hex
S-7. A.E
D3
D2
External initiator S4
Position 3
Not used
Solenoid valve 3
P3
P2
Not used
Not used
english
AS Interface - Design
Programming data for 31 Slaves
AS interface (optional)
7 hex (4 inputs / 4 outputs)
see below: Bit configuration table
F hex
(F hex)
(F hex)
S-7. F.F
D1
D0
Position 2
Position 1
Solenoid valve 2
Solenoid valve 1
P1
P0
Not used
Not used