4.1.
SVP aseptic change-over valve air opened – spring closed
4.2.
SVP aseptic change-over valve spring opened – air closed
BAA A390-D.03
Select
Version 5.04
created on/by
22.03.2017
reviewed on/by
22.03.2017
SVP aseptic change-over valve, pneum. operated
DN 010 – 020, OD 0.50" – 0.75"; ISO 008 – 015
4.
Valve function
Graf H.
Operating instructions
diaphragm – O-ring
Product path A ⇔ D opened
⇒
Connection U with elastic force closed
⇒
Control air pressure 0 bar on connection L
⇒
Safety postion
⇒
Locking pressure against product pressure 10 bar
Product path U ⇔ D opened
⇒
Connection A closed
⇒
Control air pressure 6 bar on air connection L
⇒
Locking pressure against product pressure 10 bar
Product path A ⇔ D opened
⇒
Connection U closed
⇒
Control air pressure 6 bar on air connection L
⇒
Locking pressure against product pressure 10 bar
Product path U ⇔ D opened
⇒
Connection A with elastic force closed
⇒
Control air pressure 0 bar on connection L
⇒
Safety postion
⇒
Locking pressure against product pressure 10 bar
en
1
1
2
2
Copy of original operating instructions
13