Pneumatic Data - Pentair SUDMO IntelliTop 2.0 Operating Instructions Manual

Control head
Table of Contents

Advertisement

6.6.

Pneumatic data

Control medium:
Dust content
Water content
Oil content
Temperature range
of compressed air:
Pressure range:
Air rate solenoid valve:
Connections:
The intake and exhaust air can be set separately for each solenoid valve using flow restriction screws, in order to
be able to affect the expansion and retraction rates of the process valve (see figure below).
Flow restriction screws for:
Fig. 7:
Flow restriction screws of the solenoid valves
When setting the retraction and extension rates of the pneumatic actuator, ensure that there is no con-
stant "primary pressure" during deaeration!
Keep in mind that the working conditions in the process valve area on the side of the product (flow types,
pressure variations) may result in changes in the set aeration and deaeration times.
24
Air, neutral gases
Quality classes in accordance with DIN ISO 8573-1
(5 µm filter recommended)
Quality class 7: max. particle size 40 µm,
max. particle density 10 mg/m
Quality class 3: max. pressure dew point -20°C or min. 10°C below
the lowest operating temperature
Quality class X: max. 25 mg/m
-10 ... +50 °C
2.5 ... 8 bar
110 I
/min (for ventilation and deaeration, aeration)
N
(110 I
/min
N
200 I
/min
N
(Q
value according to definition when pressure drops from 7 to 6 bar
Nn
absolute at +20 °C)
Intake and exhaust air connection
Working connections
Exhaust air R
Intake air P
english
3
3
- supplied state
- maximum typical flow rate)
G1/4
G1/8
Technical Data
Mechanical
manual control
Red lever:
left:
0
right:
1