Service/Maintenance Notification; Manual Control Function (Magnetic) - Pentair SUDMO IntelliTop 2.0 Operating Instructions Manual

Control head
Table of Contents

Advertisement

Technical Data
6.8.2.

Service/maintenance notification

Factory setting for the "Service/maintenance notification" function: not active.
When Service/maintenance notification is activated, this is indicated by a special flashing pattern - see
Chap. "17.2. Blinking pattern & fault signaling" on page 86.
The Service/maintenance notification is used to observe predefined maintenance intervals which should occur
either after an adjustable number of switching cycles or when a certain time has elapsed. PC software is used to
adjust the service/maintenance interval (number of days or switching cycles) as well as activation/deactivation of
the "Service/maintenance notification" function.
Connection to the PC is via the Service interface - see "Fig. 10: Location of the Service interface on the elec-
tronics module". Details on the "Service" menu option are described in the "PC software" manual.
Feedback, indicating that a service / maintenance is required (Service/maintenance notification), occurs when a
Service/maintenance notification is activated after the following counter readings:
Counter readings
(service interval)
Switching cycle counter V1
Switching cycle counter V2
Switching cycle counter V3
Operating duration
The resettable operating hour and switching cycle counters are reset to "0" when a Device Reset occurs.
6.8.3.

Manual control function (magnetic)

Factory setting for magnetic manual operation: active.
Deactivation is possible using PC software. Connection to the PC is via the Service interface -
see "Fig. 10: Location of the Service interface on the electronics module".
Details are described in the "PC software" manual under the "SYSTEM / Start-up" menu option.
Even the Autotune function 6 deactivates the magnetic manual control function - see Chapter "16.2.3. Autotune
sequence" on page 80, (sequence for "Autotune 6"). Compare also chapter "18.1. Magnetic manual control"
on page 90.
Fig. 10:
Location of the Service interface on the electronics module
Factory setting
10 000
50 000
50 000
365 days
Service inter-
face on the
different elec-
tronics
modules
(e.g. 24 V
and 120 V)
english
Adjustment range
(1 ... 255) x 1000
(1 ... 255) x 1000
(1 ... 255) x 1000
1 ... 65 535 days
27