13.
120 V AC DESIGN
13.1.

Electrical connection options

Fig. 28:
Connection concept 120 V AC
13.2.

Electrical data

Central power supply:
Connections: Cable gland
Power consumption (standby current): 10 mA at 120 V AC
Solenoid valves:
Max. switching capacity:
Type. Continuous output:
Power consumption per solenoid valve: 12 mA at 120 V AC
Operating mode:
Central display of the switching states: 13 mA with a power supply of 120 V AC per illuminated display; color
Outputs/binary feedback signals:
Design:
switchable output current:
Output voltage - active:
Output voltage - inactive:
68
Feedback signal output:
Cable gland:
Connection left:
Connection right:
110 ... 130 V AC, 50/60 Hz
1 x M16 x 1.5 cable gland / SW22 – for power supply and signals
(only for transportation safety device sealed with dummy plugs, remove
these before use!),
for cable diameter 5 ... 10 mm,
for wire cross-sections 0.5 ... 1.5 mm
including PE connection terminal
(tightening torque of the clamping screws max. 0.5 Nm)
1 x M16 x 1.5 – connection option for external initiator (sealed with
dummy plug - remove these before use!)
1.7 VA (per solenoid valve)
1.4 VA (per solenoid valve)
Long-term operation (100 % ED)
switching see Chapter "17. LED - Color Assignments"
S1out - S3out
Normally open contact, L switching,
short-circuit protection via automatically resetting fuse
max. 50 mA per feedback signal
≥ (operating voltage - 2 V)
max. 1 V in unloaded state
S4 out is directly connected to S4in