Summary of Contents for Pentair SPEEDEO SB-PF-SPO-003C
Page 1
The list of compatible pumps is constantly changing in accordance with releases of new models. SB-PF-SPO-003C INSTALLATION AND USER GUIDE IMPORTANT SAFETY INSTRUCTIONS, READ AND FOLLOW ALL OF THE INSTRUCTIONS, KEEP THESE INSTRUCTIONS PENTAIR WATER SOLUTIONS SB-CU-IMP-051F (this version 03/2019)
Page 2
Pentair thanks you for placing your trust in the company and purchasing a SPEEDEO®, the variable speed pump control automaton, with 3 assignable pieces of equipment. SPEEDEO® will start up the correct speed of the connected variable speed pump according to the hydraulic requirements linked to the event.
Summary PRESENTATION p 04 > Possibilities for a pump with variable speeds p 06 > Packaging contents / Functions of the device p 06 > Description INSTALLATION - SPECIFIC POINTS > Fixing connections / hygiene p 07 > Examples of installation types p 09 >...
Page 4
IMPORTANT SAFETY GUIDELINES, READ AND FOLLOW ALL OF THE INSTRUCTIONS, KEEP THESE INSTRUCTIONS GENERAL POINTS - DANGER - INSTALLERS, POOL SPECIALISTS AND OWNERS MUST CAREFULLY READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING THIS PRODUCT. - WARNING - Most countries regulate the construction, installation and operation of public swimming pools and spas, and the construction of residential pools and spas.
Page 5
- DANGER - DO NOT LET CHILDREN OPERATE THIS EQUIPMENT. - WARNING – Strictly respect the safety and handling procedures from the acid manufacturers, including protective measures for hands, body and eyes during transferring and using acid. Follow the prescribed safety precautions for handling muriatic acid intended for checking the water pH. Muriatic acid may cause serious physical harm and may damage the swimming pool equipment.
Foreword: management possibilities for a pump with variable speed control SPEEDEO is intended to optimally control (via dry contacts [of which one is shared and one is a controllable speed contact, a maximum of four]) the different rotation speeds of a variable speed filtration pump. There are usually 4 speeds: V1, V2, V3, V4.
Page 7
Functions Filtration control: - By calculating the time according to the pool temperature (automatic mode). - By programming a 24 hour cycle (makes it possible to benefit from off hours). - By integrating the frost protection function (activation of the filtration below 3°C, modifiable value).
Manufacturer’s plate Water or air Serial number VALID temperature sensor SB-PF-SPO-003C SB-SE-TEC-006A QC Passed MADE IN ITALY Pentair International Sarl 1234ABCD1234ABCD1234ABCD01 Mfg Year (see p06) SCAN Avenue de Sévelin 18 230 V 50 Hz~/IP64/3.2 W Apr-2019 CH-1004 Lausanne, Switzerland 433.4 MHz...
Wall fixing - This device is intended to be used inside, installed in a technical room which cannot be accessed by children. - Set the device at a height lower than 2 m using three screws (4 to 5 mm diameter) in appropriate plugs for the type of support and fix the device vertically on a clean support which is able to bear a minimum vertical load of 5 kg.
Page 10
Electrical connections regulation - The device must be installed by a qualified technician according to valid local regulation - This device is permanently connected. - The power supply to the device is cut by its interrupter, which must be close and must remain accessible at all times.
Examples of installation types - Inlet connections: Water temperature, cover presence sensor - Outlet connections: Heating, electro-pneumatic valve, solenoid valve Indicative connections SPEEDEO ® VA R I A B L E S P E E D P U M P 01:03 Water:+24.3°C Filtration: V2 S1:OFF S2:ON S3:OFF...
Water and air temperature probes. SPEEDEO is supplied with a temperature probe which is suitable for water. It is possible to mount a second temperature probe for the air temperature used to manage the frost protection process of heated technical rooms. The probe time can be staggered via the Temperature Menu >...
3 - On the Filtration Speed / Type sub-menu, select 4 speeds and hold down Valid. PENTAIR VS1 (Superflo, Ultraflow, SuperMax and S5P2R): Connections and functions Control the speeds S1 < S2 < S3 < S4 and S4 at 100% on the pump drive.
ZODIAC FloPro VS: Connections and functions Control speeds 1 < 2 < 3 < 4 on the pump drive - Control all operation lengths at '0' !! Terminal under the user interface!! COMMON INPUT 4 INPUT 3 INPUT 2 INPUT 1 1 - Connect the cables in accordance with the diagram.
SPECK 90 Eco Motion: Connections and functions On the pump, control the speeds N1 < N2 < N3 < N4 and N4 at 100% / 'EXTERNAL = FIX SPEED' and 'SIGNAL = CONTINUED'. - The pump functions for 5 minutes at maximum speed after starting. Common = 50 Speed 1 = 51 Speed 2 = 52...
Main menu Time Water temperature Pairing with a SOLEO 01:22 Water:+26.6°C Operating speed Filtration : S3 S1:OFF S2:ON S3:OFF Status of outlets S1, S2, S3 Air:+26.8°C WASHING Air temperature Filter clean required (if 2 sensor connected, see p06) (not displayed for automatic washing on pneumatic valve) Radio menu (radio pairing between SOLEO and SPEEDEO) This symbol (antenna) indicates that SPEEDEO is connected to a SOLEO.
Access to restricted access mode 'Install' SPEEDEO controls the equipment in the technical room, and the wrong settings may have serious consequences for the safety of the pool. Because of this, access to certain initial configuration functions is reserved for professionals, or people whose experience enables them to modify these parameters while being fully aware of the consequences.
Menu: Filtration Length (daily) / Algorithm SPEEDEO proposes 4 different algorithms to suit different preferences concerning the ratio of the number of hours for filtration according to the water temperature. - Once the SPEEDEO is linked to a SOLEO, this menu Filtration Length disappears. The SOLEO will manage the filtration length.
Menu: Filtration Length / Auto/On/Off/Timer/Shock Mode - Once the SPEEDEO is linked to a SOLEO, this menu Filtration Length disappears. The SOLEO will manage the filtration length. Home menu > Filtration Length menu: Select current mode: AUTO = Automatically calculates the filtration length according to the water temperature.
Inlet: connection for the end of a cover line 230 V ~ The contact is closed when the cover is covering the pool 1 - Connect the cables in accordance with the diagram. 2 - Start the secured Install menu (from the main menu, simultaneously hold down Esc and Valid for 3 secs. A star appears in the top right corner of the home screen).
This contact is closed (active outlet) while the filtration is running, whatever the rotation speed. The connected control is guaranteed to function while the filtration pump is running. PENTAIR IntelliChlor: Connections and functions Connect the pump to the 230 V, connect to the 10-m long IntelliFlo cable (ref 350122), the green/yel- low to the 'BUS', adhering to the colours.
Outlet: heating connection Connection Connection via a contactor via the safety shutdown (flow switch) NEUTRAL (N) EARTH PHASE (L) An outlet is a dry contact and does not supply any voltage. 1 - Connect the cables in accordance with the chosen diagram. 2 - Start the secured Install menu (from the main menu, simultaneously hold down Esc and Valid for 3 secs.
Page 23
Outlet: solar heating connection An outlet is a dry contact and does not supply any voltage. 230 V ~ Solar T° SB-PD-PRO-004B 1 - Connect the cables in accordance with the diagram. 2 - Start the secured Install menu (from the main menu, simultaneously hold down Esc and Valid for 3 secs. A star appears in the top right corner of the home screen).
Outlet: connection for lighting below 1,600 W An outlet is a dry contact and does not supply any voltage. 230 V ~ PHASE (L) < 1600 W NEUTRAL (N) 1 - Connect the cables in accordance with the diagram. 2 - Start the secured Install menu (from the main menu, simultaneously hold down Esc and Valid for 3 secs. A star appears in the top right corner of the home screen).
Outlet: connection for a pneumatic valve (FILTER WASHING) 230 V ~ An outlet is a dry contact and does not supply any voltage. 3 bar min 1 - Connect the cables in accordance with the diagram. 2 - Start the secured Install menu (from the main menu, simultaneously hold down Esc and Valid for 3 secs. A star appears in the top right corner of the home screen).
Assisted backwash: Backwash support for the lter on the 6-way valve. SPEEDEO supports you in washing the filter by chronologically proposing the different required steps. Welcome menu > Filter Washing: 1 - On the Filter washing sub-menu, enter the filtration length (factory pre-set at 100 hours), which activates the alert requesting filter washing, the desired washing time - M a n u a l B ac k was h length (factory pre-set at 70 secs) and enter the desired filter rinsing time length...
Navigation menus (1/2) - Filtration length (only in solo mode without Soleo) Filtration: AUTO, SHOCK, TIMER, OFF, ON Start: 07:00 End: Auto mode: Eco, Normal, Turbo ORP priority: ON, OFF Algorithm: t=T VS, BlueVS, T/2Cla, BluCla Eco mode: -30% Turbo mode: +30% Antifreeze: +3°C Cover open: YES, NO - Filtration speed...
Page 28
Navigation menus (2/2) - Temperatures Heating Heating: AUTO, OFF Set point: 25 °C Range: YES, NO Start: 7:00 End: 23:00 Priority: YES, NO Tempo Stop: 01 min. Solar Solar: AUTO, OFF Temp di erence: 3 °C Delta heating: -3 °C Calibration Temp.
How to update the internal rmware 1.1 - Unzip the MAJ_Speedeo2.zip file to obtain the Speedeo2.bin file. 1.2 - Copy the Speedeo2.bin file to the main folder of the USB stick recognised formatted in FAT 16 or FAT 32. 2.1 - Remove the soft cover, then remove the orange cover SPEEDEO ®...
Variations in the RedOx (ORP) according to the pH and the chlorine rate in water without a stabiliser at a temperature of 18°C.
Page 32
Ave. de Sevellin 18, CH-1004 - LAUSANNE, Switzerland Copyright – Limited Licence: except as speci cally permitted herein, no portion of the content of this document may be reproduced in any form or by any means without the prior written permission of Pentair International SRL.