8.1.2 User Menu – Settings Screen
The basic settings are displayed in the order they are shown on the Settings screen:
Figure 11: User Menu – Main Settings screen
1) SCALE
2) SMOOTHING

8.1.3 Changing Basic Settings

For other settings and functions refer to Advanced Settings below.
OPTION
SETTING
1
Scale
2
Smoothing
3
Alarm 2
(Early Warning alarm)
4
Alarm 1
(High alarm)
5
Timer
6
4–20 mA Smoothing

8.2 ENGINEERING FUNCTIONS

8.2.1 Advanced Settings

The advanced settings are shown in the order they are accessed on the Engineering screen (see also Main Screens
on page 22):

Figure 12: Engineering Menu screen

1) USER PIN
2) UNLOCK FEATURES

8.2.2 Changing Advanced Settings

OPTION
SETTING
3
4 mA trim
4
20 mA trim

8.2.3 Factory Reset

1. Open the Engineering screen (see Main Screens on page 22).
2. Select Option 5
the procedure).
The screen now displays System init...
3. When the factory pre-sets have been restored, the control unit will restart automatically.
INSTALLATION AND OPERATION MANUAL – OWNER'S RECORD FFA MANUAL – FILTER FAILURE ALARM
3) ALARM 2 (EARLY WARNING)
4) ALARM 1 (HIGH ALARM)
VALUES
1–5, 10, 15, 25, 50, 75, 100,
125 ... 950
1, 2, 5, 10, 30, 60, 90, 900
Increments +5
Increments +5
1, 3, 10, 30, 60, 300, 600
1, 2, 5, 10, 30, 60, 90, 300
VALUES
±5%
of factory setting
then select the green tick
DESCRIPTION
Multiples of x. Changes the scale to adjust the sensor
sensitivity.
Sets the number of samples used for the calculation of the
average output value (shown on the bar).
Percentage. Sets the threshold for the early warning alarm.
This value cannot be greater than Alarm 1.
If the alarm is set to 0, it is disabled.
Percentage. Sets the threshold for the high alarm.
Note: adjusting this alarm setting may affect Alarm 2; ensure
that the alarms are set at the correct level.
Alarm delay, in seconds.
In seconds. Changes the number of samples used
for the calculation of the average output value for the
4–20 mA interface.
3) 4 mA TRIMMING
4
mA
4) 20 mA TRIMMING
20
mA
DESCRIPTION
Set trim using digits from 0–9. Values outside the boundaries are
ignored.
to initiate the factory reset (or select the red Fail
5) TIMER
6) SMOOTHING 4–20 mA
5) FACTORY RESET
6) SOFTWARE VERSION
icon to cancel