TROUBLESHOOTING
The appliance has been tested before being put into
service.
The information provided below is intended to assist
in the identification and correction of any anomalies
and malfunctions which might occur during use.
Fault
The heating elements do
not come on
When the water control
knob is turned to 2
(automatic rapid filling),
water is supplied
continuously, until it
overflows
When the water control knob is
turned to 2 (automatic rapid filling),
no water comes out of the tap
When the water control knob is
turned to 3 (automatic slow filling),
slow filling does not take place
FAULT
The user can solve some of these problems himself,
but for others specific technical knowledge or skill is
required, and so they must only be carried out by
qualified staff with recognised experience acquired
in the specific sector of operation.
Cause
Electrical connection not made
correctly
Safety thermostat tripped
Switch faulty
Blockage in pressure switch circuit
Pressure switch faulty
Filler solenoid valve faulty
Pressure switch connection not made
correctly
Water connection not made correctly
Water level maintenance solenoid
valve connection not made correctly
Water level maintenance solenoid
valve faulty
- 11 -
Remedy
Check the connection of the electrical
wires
Carry out the appliance reset
(see page 9)
Replace the switch
Important
Contact the after-sales service
Clean the circuit
Important
Contact the after-sales
service
Replace the pressure switch
Important
Contact the after-sales service
Replace solenoid valve
Important
Contact the after-sales service
Check the pressure switch
connection
Important
Contact the after-sales service
Check the water connection
Important
Contact the after-sales service
Check the solenoid valve
connection
Important
Contact the after-sales service
Replace solenoid valve
Important
Contact the after-sales service
6
IT
GB
DE
FR
ES
English