Angelo Po 0G1CP1EC Use And Installation Manual page 31

Pasta cooker
Hide thumbs Also See for 0G1CP1EC:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 19
INSTALLATION OF THE APPLIANCE
All installation stages must be considered right from
production of the general layout. Before starting the-
se stages, as well as deciding the place of installa-
tion, if necessary, the person authorised to carry out
these operations must organise a "safety plan" to
protect the people directly involved, and he must
also ensure strict compliance with all legal require-
ments, especially those relating to mobile work-si-
tes.
The place of installation must have all the connec-
tions needed to supply the appliance and dispose of
the production residues, must be suitably lit and
must meet all legal health and hygiene requiremen-
ts to prevent the contamination of the foods.
If necessary, fix the exact position of each individual
appliance or subassembly by mark coordinates to
locate them correctly.
INSTALLATION OF DISMANTLED PARTS
The appliance is delivered with some components
dismantled and they have to be fitted during instal-
lation. Specifically, the floor-mounted feet must be
fitted (A).
LEVELLING
Adjust the floor-mounted feet (A) to level the appli-
ance.
ASSEMBLY APPLIANCES IN BANKS
To assemble appliances in banks (side by side) pro-
ceed as described below.
1 - Pull off the knob (A).
2 - Undo the screws and remove the control panels (B).
3 - Apply masking tape to the edges to be placed
side by side.
4 - Apply food-approved sealant to the edges to be
placed side by side.
5 - Place the appliances alongside each other and
level them (see "levelling").
6 - Connect the appliance using the screws and
nuts (C-D).
7 - Remove the excess sealant and the masking
tape.
8 - Apply the sealant to the inside of the lid (E), and
fit it to cover the fixing zone.
Appliances must be at some distance from the wall
(at least 5 cm if the wall is not designed to be resi-
stant to a temperature of at least 150°C)
Install in accordance with the relevant legislation,
regulations and specifications in the country of use.
A
B
C
- 13 -
IDM-39603601100.tif
A
IDM-39603601100.tif
E
D
IDM-39613501300.tif
IT