Important
The connection must be made by authori-
sed, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
pliance is supplied with operating voltage
400V/3N (230V/3 available on request).
Specify the correct voltage for your device;
it cannot be modified after purchase.
Caution - warning
Before doing any work, cut off the mains
electricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker (A)
with overload cutout and differential safety
breaker close to the appliance.
2 - Open the hatch (B).
3 - Undo the screws and remove the guard (C).
4 - Connect the circuit-breaker (A) to the terminal
board (D) of the appliance as shown in the dia-
gram and in the electrical system diagram at the
Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The appli-
ance is supplied with operating voltage
400V/3N (230V/3 available on request).
Specify the correct voltage for your device;
it cannot be modified after purchase.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker (A)
with overload cutout and differential safety
breaker close to the appliance.
2 - Pull off the knob (B).
3 - Undo the screws and remove the control panel
(C).
4 - Connect the circuit-breaker (A) to the terminal
board (D) of the appliance as shown in the dia-
gram and in the electrical system diagram at the
back of the manual.
ELECTRICAL CONNECTION (0G1CP1EC)
ELECTRICAL CONNECTION (0G1CP1E)
A
C
back of the manual. Use a cable with at least
H05RN-F characteristics.
Important
When connecting, take care to connect
the neutral and earth lines.
5 - Replace the guard (C) and retighten the
screws.
6 - Close the door (B) when the operation is com-
plete.
A
B
C
Use a cable with at least H05RN-F characteris-
tics
Important
When connecting, take care to connect the
neutral and earth lines.
5 - Replace the control panel (C) on completion of
the operation.
- 15 -