The appliance has been tested before being put into service.
The information provided below is intended to assist in the identification and correction of any anoma-
lies and malfunctions which might occur during use.
The user can solve some of these problems himself, but for others specific technical knowledge or skill
is required, and so they must only be carried out by qualified staff with recognised experience acquired
in the specific sector of operation.
NOTE: For all requirements contact the agents or the headquarters of Angelo Po which can
be found in the contacts section of the website http://www .angelopo .com .

Fault

The appliance does not
switch on
Smell of gas
Cooking cycle does not start
or stops suddenly
The burner does not light or
goes out suddenly
Burner does not light or goes
out suddenly with "E12"
alarm signalled
If the problem or fault noticed is not amongst those
listed in the table, consult the "Key to Alarms" table
provided below.
The information provided below s intended to
identify the alarm signals which appear on the
display (11).
NOTE: Press button (14) to reset the alarm
and the cooking cycle restarts automatically; if
this is not the case, press the start key (2) .
26
FAULT

TROUBLESHOOTING

Cause
Fuse "blown"
Safety or protection device (safe-
ty thermostat or overload cutout)
tripped.
Electronic circuit board damaged
Gas leaks in supply system
Control board electronic circuit
board damaged
Alarm triggered
Gas valve faulty
Air intake in base obstructed
Ignition plug wires disconnected
or damaged
Ignition plugs dirty or damaged
Ignition monitoring device faulty

TABLE OF ALARM INDICATIONS

Remedy
Replace the fuse (see "installation
manual").
Press device reset button.
Contact the after-sales service.
Check the tightness of the system
Contact the after-sales service
Consult the "Key to Alarms" table
Replace gas valve
Clean the air intake
Reconnect or replace the wires
Clean or replace the plugs
Replace the device