Fault - Angelo Po 190TP0 Use And Installation Manual

Cooking plate
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 33
CHECKING GAS PRESSURE
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panel (B).
4 - Undo the screw (D) of the pressure connection.
5 - Connect the pressure gauge (E) to the pressure
test point (F).
6 - Turn the gas supply tap back on.
7 - Light all the burners and turn the knobs to the
full flame setting (see page 11), then check that
the pressure reading complies with the values
provided in the table at the back of the manual.
8 - Turn off the burners, disconnect the pressure
gauge and return all components to their initial
condition on completion of the operation.
TROUBLESHOOTING
The appliance has been tested before being put
into service.
The information provided below is intended to as-
sist in the identification and correction of any anom-
alies and malfunctions which might occur during
use.
Faults
Smell of gas
The pilot light does not ignite
The pilot light goes out
The flame is yellow
Burner control knob is stiff

FAULT

The user can solve some of these problems
himself, but for others specific technical knowl-
edge or skill is required, and so they must only
be carried out by qualified staff with recog-
nised experience acquired in the specific sec-
tor of operation.
Causes
Occasional leak because
flame has gone out
The spark ignition devices
are not working
Air in pipelines due to
long period out of use
The thermocouple has not
warmed up enough
Burner dirty, heat exchange pipes
clogged, condensation drips
Gas control valve malfunction
- 15 -
E
A
C
C
B
Turn off the gas supply tap and
ventilate the room
Check that the ignition devices
are in good working order.
Light by hand with a naked light.
Important
Contact the after-sales service
Make more attempts
to light the flame
Make more attempts
to light the flame
Important
Contact the after-sales service
Important
Contact the after-sales service
F
D
IDM-39614801300.tif
5
Remedies
English
IT
GB
DE
FR
ES

Advertisement

Table of Contents
loading

This manual is also suitable for:

191tpg291tpcg

Table of Contents