  • ENGLISH, page 33
GAS CONNECTION
Important
Those authorised to carry out this opera-
tion must have experience acquired and
certified in the specific sector, must make
the connection to the proper standards,
and must comply with all the relevant regu-
lations and legislation. Once the connec-
tion has been made, before the appliance is
put into operation a general check must be
made to ensure there are no gas leaks.
To make the connection, connect the mains line to the
appliance's connection pipe, fitting a shut-off tap (A), to
allow the gas supply to be cut off when necessary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessi-
ble position and its status (on or off)
must be obvious at a glance.
CONNECTION OF FUME EXHAUST VENT
Important
Make the connection in compliance with
the relevant legal requirements, using ap-
propriate and recommended materials.
IT
Connecting to a flue with
GB
natural draught
To carry out this operation,
proceed as follows.
DE
1 - Connect the appliance's
exhaust outlet to the flue
FR
(A) using a line comply-
ing with the dimensions
ES
shown in the diagram.
Connecting to a fan extractor hood
To carry out this operation, proceed as follows.
1 - Position the appliance underneath the hood (B)
and connect a line of the dimensions shown in
the diagram to the appliance's exhaust outlet.
English
B
The fan of the extraction system must
switch on automatically when the gas sup-
ply tap is turned on.