Maintenance
Specific tooling
020851Y Camshaft timing pin
020852Y Crankshaft timing pin
Check if the clearance between the cam on the shaft and the tappet is correct.
If not, repeat the valve clearance adjustment procedure.
Calibrated pad thickness
Pad thicknesses for adjusting valve clearance correctly:
1.75 mm (0.0689 in)
1.77 mm (0.0697 in)
1.80 mm (0.0709 in)
1.82 mm (0.0716 in)
1.85 mm (0.0728 in)
1.87 mm (0.0736 in)
1.90 mm (0.0748 in)
1.92 mm (0.0756 in)
1.95 mm (0.0768 in)
1.97 mm (0.0775 in)
2 mm (0.0787 in)
2.02 mm (0.0795 in)
2.05 mm (0.0807 in)
2.07 mm (0.0815 in)
MAIN - 86